PSEN cs4.1p/M12
Operating Manual PSEN cs4.1p/M12
1003293-EN-08
| 31
Mechanical data
541159
541160
Operating distances
for actuators
PSEN cs4.1
PSEN cs4.1
Assured operating distance Sao
8 mm
8 mm
Typical operating distance So
11 mm
11 mm
Assured release distance Sar
20 mm
20 mm
Typical release distance Sr
14 mm
14 mm
Repetition accuracy switching
distances
10 %
10 %
Change of operating distance
with temperature changes
+-0,01mm/°C
+-0,01mm/°C
Typ. Hysteresis
2 mm
2 mm
for actuators
PSEN cs2.1
PSEN cs2.1
Assured operating distance Sao
10 mm
10 mm
Typical operating distance So
25 mm
25 mm
Assured release distance Sar
33 mm
33 mm
Typical release distance Sr
29 mm
29 mm
Repetition accuracy switching
distances
10 %
10 %
Change of operating distance
with temperature changes
+-0,1mm/°C
+-0,1mm/°C
Typ. Hysteresis
3 mm
3 mm
Min. distance between safety
switches
100 mm
100 mm
Sensor flush installation in accord-
ance with EN 60947-5-2
Yes, follow installation
guidelines
Yes, follow installation
guidelines
Connection type
M12, 8-pin male connector
M8, 8-pin male connector
Cable
Li9Y11Y 8 x 0,14 mm2
Li9Y11Y 8 x 0,14 mm2
Material
Top
PBT
PBT
Max. torque setting for fixing
screws
0,8 Nm
0,8 Nm
Dimensions
Height
37 mm
37 mm
Width
26 mm
26 mm
Depth
18 mm
18 mm
Weight of safety switch
40 g
35 g