PSEN cs4.1p/M12
Operating Manual PSEN cs4.1p/M12
1003293-EN-08
| 23
Safety switches PSEN cs4.1 with actuator PSEN cs4.1
1. Drill holes in the mounting surface to secure the actuator and safety switch (see
2. Use two screws to fix the safety switch in place. Do not fully tighten the 2nd screw on
the safety switch.
3. Attach the screws for the actuator, leaving a distance of 3 … 6 mm between the screw
head and plate.
4. Slide the actuator on to the screws. The arrows on the labelled surfaces of the safety
switch and actuator must face each other. Align the actuator and tighten the screws.
Parallel assembly
Orthogonal assembly
5. Align the safety switch and tighten the screws.
6. Close the mounting holes using the seals provided (see diagram).
Use the seals [1] for UL approval or [4] without UL approval.