PSEN cs4.1p/M12
Operating Manual PSEN cs4.1p/M12
1003293-EN-08
| 24
[1]
[2]
[3]
[4]
Legend
[1] Side seal with UL approval
[2] Bottom seal
[3] Top seal, sensing side
[4] Side seal without UL approval
7. Use the seals to close the mounting holes on the sensing face of the safety switch (see
diagram, [3]).
8. Use the seals [2] to close the unused mounting holes on the actuator (see diagram, [2]).
Safety switches PSEN cs4.1 with actuator PSEN cs2.1
1. Drill holes in the mounting surface to secure the actuator and safety switch (see
2. Use two screws to fix the safety switch in place. Do not fully tighten the 2nd screw on
the safety switch.
3. Attach the screws for the actuator, leaving a distance of 3 … 6 mm between the screw
head and plate.