![Pilz PNOZ s50 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/pilz/pnoz-s50/pnoz-s50_operating-manual_1556820064.webp)
Technical details
Operating Manual PNOZ s50
1002194EN02
64
9.1
Safety characteristic data
Operating
mode
EN ISO
138491:
2008
PL
EN ISO
138491:
2008
Category
EN IEC
62061
SIL CL
EN IEC
62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
138491:
2008
T
M
[year]
All
PL e
Cat. 4
SIL CL 3
7,83E10
SIL 3
6,81E05
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
The safetyrelated characteristic data (PFH, PFD) are mean values. They have been calcu
lated at an average ambient component temperature of 40 °C and apply for the ambient
temperature range stated in the technical details.