Wiring
Operating instructions PMCprimo C
1002242-EN-03
29
Output circuit
Digital output
DI 5
5
6
12
X40
DI 4
4
DI 2
DI 1
DI 3
14
O1:1
13
DI 6
O1:2
O1:3
O1:4
O1:5
O1:6
7
15
+24 V
0 V
+24 V
I/O-GND
24 VDC, referenced to
earth (X40/15)
Connection
6.6
Interfaces
6.6.1
Overview
Four RJ45 sockets with interfaces are available on the front.
Socket X42-X45
Connector
Description
X45
X44
X43
X42
8
1
8
1
8
1
8
1
X45
SafetyNET p interface RTFL "IN"
X44
SafetyNET p interface RTFL "OUT"
X43
Ethernet interface
X42
Depending on the unit type:
- 2 CANopen interfaces
- 1 CANopen/1 PROFIBUS DP interface
(connection via fieldbus junction box on the servo
amplifier PMCprotego D, see section entitled
Device properties [
14]
)
Socket assignment