Function description
Operating Manual PIT m4SEU
1004648-EN-02
| 46
Output
SIo0 ... SIo3
Stop MSO pre-
selection
Key removed
ack
Resumption MSO pre-
selection
keylock
Key
Key 2
Push button
Output
MSO
display
MSO
MSO2
MSO2
MSO2
MSO1 selected [8h]
MSO2 selected [9h]
MSO2
[Fh]
MSO1 selected [8h]
MSO1
MSO2
[9h]
[Ch]
MSO2 selected [9h]
MSO1
200 ms [1]
Fig.: Exiting the operating mode preselection after the transponder key has been removed, with DIP switch setting [D7]
Legend
To assign the terminal designations to the short descriptions, please refer to the table in
t
ack
Acknowledge Time min. 120 ms.
keylock
Control signal is generated by the controller and must be present for at
least 20 ms for the signal state to be adopted
"0" signal
Locking the change of operating mode and/or ending an oper-
ating mode preselection
"1" signal
Enabling the change of operating mode and/or resuming an
operating mode preselection
ack
Control signal is generated by the controller. "0" signal must be present for
at least 20 ms for the signal state to be adopted.
"0" signal
Preventing the switching of operating mode outputs
"1" signal
Enabling the switching of operating mode outputs
display MSO
Display element is lit
Output
SIo0 ... SIo3
Interface for control information
Output MSO
Operating mode outputs