Содержание 774133

Страница 1: ... instructions and the current regulations for health and safety at work and accident prevention Only use the unit in accordance with its intended purpose Please also take note of the values in the Technical details section Transport storage and operating conditions should all conform to the standards as stated under Technical details Do not open the housing or undertake any unauthorised modificati...

Страница 2: ... g E STOP button is not operated Safety outputs 14 and 24 and auxiliary output Y32 are energised Input circuit is open e g E STOP button is operated Safety outputs 14 and 24 and auxiliary output Y32 are de energised Functions If there is a high signal 24 VDC at input Y5 for at least 250 ms output Y32 switches to diagnostic mode It is controlled via a driver that is available as an accessory or tha...

Страница 3: ...e unit checks whether closed safety gates are opened and closed again when operating voltage is applied The number of safety contacts can be increased by connecting a contact block e g PZE X4 1P or external contactors Installing the relay Caution Electrostatic discharge can damage components on the safety system Ensure against discharge before touching the safety system e g by touching an earthed ...

Страница 4: ...e used Output Y32 should be used exclusively as an auxiliary output e g for communication with a PLC or display Use flywheel diodes to drive contactors or relays with the safety auxiliary outputs When connecting magnetically operated reed proximity switches ensure that the max peak inrush current on the input circuit does not overload the proximity switch Preparing the unit for operation Connect t...

Страница 5: ...rs in series to the reset circuit The feedback loop is monitored The feedback loop must be closed a maximum of 150 ms after the respective output has switched off Using the safety relay as a single unit Please note If you are using the PNOZ e1 1p on its own make the OR connection see Linking the units Linking the units When linking several units please note The PNOZ e1p can only be linked from ver...

Страница 6: ...r dérogation au schéma du circuit d entrée Operation The unit detects the set operating mode on start up During this time the POWER LED will flash The unit is ready for operation when the POWER LED is lit continuously Status indicators CH 1 and or CH 2 lights Safety output 14 and or 24 is enabled CH 1 and or CH 2 goes out Safety output 14 and or 24 disabled Faults Fault indicator LED CH 1 or LED C...

Страница 7: ... des court circuits GB GB GB GB GB D D D D D F F F F F Anschlussbeispiel UND Verknüpfung von Unit 1 und Unit 2 ODER Verknüpfung von Unit 2 und Unit 3 einkanalig automatischer Start ohne Querschlusserkennung Connection example AND link Unit 1 and Unit 2 OR link Unit 2 and Unit 3 single channel automatic reset without detection of shorts across contacts Exemple de raccordement Liaison ET de l unité ...

Страница 8: ...les câbles Démontage d un bornier à vis Technical details Electrical data Supply voltage UB Voltage tolerance UB Power consumption at UB without load Residual ripple UB Semiconductor outputs Safety outputs N O Auxiliary output N O Switching capability semiconductor outputs 2 outputs under load 1 output under load Total power ext load semiconductor outputs Voltage and current at Input circuit rrese...

Страница 9: ...EN 60947 1 Pollution degree Overvoltage category Ambient temperature Storage temperature Protection type Mounting e g control cabinet Housing Terminals Mechanical data Cable cross section screw terminals 1 core flexible 2 core same cross section flexible with crimp connectors without insulating sleeve flexible without crimp connectors or with TWIN crimp connectors Cable cross section spring loaded...

Страница 10: ...dern Deutschland EC Declaration of Conformity This these product s comply with the requirements of Directive 2006 42 EC of the European Parliament and of the Council on machinery The complete EC Declaration of Conformity is available on the Internet at www pilz com Authorised representative Norbert Fröhlich Pilz GmbH Co KG Felix Wankel Str 2 73760 Ostfildern Germany Déclaration de conformité CE Ce...

Страница 11: ... 11 Notizen Notes Notes ...

Страница 12: ...er Homepage oder nehmen Sie Kontakt mit unserem Stammhaus auf Nos filiales et partenaires commerciaux nous représentent dans plusieurs pays Pour plus de renseignements consultez notre site internet ou contactez notre maison mère In many countries we are represented by our subsidiaries and sales partners Please refer to our Homepage for further details or contact our headquarters www pilz com Pilz ...