Supplementary data
Operating Manual PNOZ s30
1001715-EN-15
94
9.3.1.3
Connection
L+
L-
K1
K2
23
21
13
11
Y13
A2
22
24
14
S11
S21 S34
12
A1
IN2
IN1
Y1
Y2
GND
Y35 Y34
Y12 Y11
Y33
Y10
Y32
Y30
Y31
K1
K2
S3
F1
pnp
pnp
PNOZ s30
33
S11 S21
Y32
42
S12
13
A1
S22 S34
23
41
A2
14
24
34
PNOZ s4
9.3.2
Incremental encoder connection
9.3.2.1
Features
PNOZ s30
}
Speed monitoring:
Monitoring for overspeed for the operating modes "Setup" and "Automatic", which are
selected with the switch S1.
–
The operating mode "Setup" is selected if the select input SEL1 is activated. Over-
speed is detected during setup at >= 50 Hz and the output Rel. 2 switches off.
–
The operating mode "Automatic" is selected if the select input SEL2 is activated.
Overspeed is detected during automatic mode at >= 3000 Hz and the output Rel. 2
switches off.
–
If a speed of 2800 Hz is exceeded, the semiconductor output Out1 switches in auto-
matic mode and a message (advance warning) is output via the PLC.