PSEN cs5.1 M12/8
Operating Manual PSEN cs5.1 M12/8
1003419-EN-06
18
PIN
Connection
designation
Function
Wire colour
7
A2
0 V UB
blue
8
Y1
Diagnostics input
red
The wire colour also applies for the cable available from Pilz as an accessory.
Connection to evaluation devices
Make sure that the selected evaluation device has the following property:
}
OSSD signals are evaluated through 2 channels with feasibility monitoring
Please note:
}
}
The use of Safety Device Diagnostics is described in the System Description "Safety
Device Diagnostics".
CAUTION!
Do not connect the signal output to 0 V!
If the signal output Y32 is connected to 0 V, the safety switch may be dam-
aged as a result. Connect the signal output Y32 to a consumer, e.g. to the
input on a control system, or leave the signal output unconnected. Also note
).