PSEN cs5.1 M12/8
Operating Manual PSEN cs5.1 M12/8
1003419-EN-06
30
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators:
Legend
LED off
LED on
LED flashes (500 ms on, 500 ms off)
LED flashes quickly (50 ms on, 950 ms off)
Normal mode
LED status
Switch status
Device
Green
Ready for operation
Safety Gate
yellow
Actuator is within the response range
Off
Actuator is outside the response range
Input
yellow
Both safety inputs are high
Off
Both safety inputs are low
Error display
LED status
Switch status
Remedy / measure
Device
Safety Gate
Input
red
Off
Off
Internal error on
switch
Change the switch.
red
yellow
yellow
Supply voltage is
outside the toler-
ance range
Ensure the voltage supply
corresponds to the
.
yellow
Display not
definitive
Display not
definitive
Supply voltage is at
the limit of the toler-
ance range
Ensure the voltage supply
corresponds to the
.