Operation
19
Operation
Inverter
The power supply delivers a controlled level of high frequency power to the sealing coil. The
operator panel allows the user to control the level of power. On hand held systems, the sealing
time during which power is supplied to the coil is also adjustable. The power supply includes a
rectifier section, an inverter and a series inductor for delivering a high frequency, sinusoidal
output to the sealing coil.
Diagnostic Lights
There is a group of diagnostic indicators on the operator panel which show how the power
supply is performing. Refer to the troubleshooting section starting on page 25 for advice on how
to interpret the different lights. A brief description of their function will be given here.
Setup -
NOT USED. Refer to the Stalled Bottle / Missing Foil System manual for further
details.
Inverter On
- Indicates that power is being supplied to the sealing coil.
Alarm Fault
- Lights when the coil output has dropped below the threshold set by the alarm
set point operator on the panel. This is used to indicate that the power supply is not
Figure 7
- Operator Panel