background image

 

 

 

 

CONTENTS 

 

1

 

INTRODUCTION

 ......................................................................................................................................... 4

 

1.1

 

Unpacking the HS1

 ............................................................................................................................. 4

 

1.2

 

Handling the HS1.

 ............................................................................................................................... 4

 

1.3

 

HS1.

 ...................................................................................................................................................... 5

 

2

 

INSTALLATION

 ........................................................................................................................................... 5

 

2.1

 

Installing a single axis HS1 unit.

 ....................................................................................................... 5

 

2.2

 

Installing a two axis HS1 unit

 ............................................................................................................ 6

 

2.3

 

Installing a three axis HS1 unit

 ......................................................................................................... 6

 

3

 

GROUND LOOPS

 ....................................................................................................................................... 7

 

3.1

 

Prevention and identification of ground loops

 ................................................................................. 7

 

4

 

OPERATING THE NANOPOSITIONING STAGE

 .................................................................................. 7

 

4.1

 

Operating in closed loop mode

 ......................................................................................................... 7

 

4.2

 

Care during operation

 ......................................................................................................................... 8

 

 

 

Содержание HS1

Страница 1: ...1 INSTALLATION AND OPERATION MANUAL HS1 PIEZOCONCEPT 15 Rue du Bocage 69008 LYON France ...

Страница 2: ...om the PIEZOCONCEPT controller first set the command voltage to 0 0V then turn the AC power to the PIEZOCONCEPT controller off and finally wait one minute before disconnecting The HS1 has no user serviceable parts Only trained service personnel should perform service IMPORTANT All Technical Information recommendations and examples related to PIEZOCONCEPT Products made in this manual are based on i...

Страница 3: ...ATION 5 2 1 Installing a single axis HS1 unit 5 2 2 Installing a two axis HS1 unit 6 2 3 Installing a three axis HS1 unit 6 3 GROUND LOOPS 7 3 1 Prevention and identification of ground loops 7 4 OPERATING THE NANOPOSITIONING STAGE 7 4 1 Operating in closed loop mode 7 4 2 Care during operation 8 ...

Страница 4: ...cientific instrument and therefore requires special handling in order to ensure proper operation Mishandling can cause permanent damage to the nanopositioning stage To ensure a long and useful life the following guidelines should be strictly followed Never insert anything into the EDM grooves The EDM grooves are the cuts that form the flexure hinges and separate the moving portion of the stage Do ...

Страница 5: ... 2 1 Installing a single axis HS1 unit To install a single axis HS1 use the following steps On the surface that the HS1 is to be mounted on tap M3 holes on a 52 50X52 50mm square Make sure the surface to be mounted to is clean flat and free of burs Using a lint free cloth gently wipe off the bottom of the HS1 to remove any particles or dust Use M3 Socket screws to secure the stage Use a maximum to...

Страница 6: ...t head screws Do not hold on to the bottom or Y axis while loosening To install a two axis HS1 system use the following steps 1 Install the first or bottom HS1 Y axis using the procedures described above in Section 2 1 2 Using a lint free cloth gently wipe off the top of the installed HS1 and the bottom of the adapter plate to remove any particles or dust 3 Using four M2 5 screws provided bolt the...

Страница 7: ...ews and the mounting surface may short circuit the ground loop In a few cases this may not be an effective method When this occurs please identify high current sources returning to ground through your mounting surface Mounting surfaces should never be used as the electrical ground current path for any instrumentation such as vacuum pumps computers etc Should you observe unexpected oscillations in ...

Страница 8: ...ow 1 minute for the PZT actuators to discharge before disconnecting For more information see the PIEZOCONCEPT CONTROLLER OPERATION MANUAL 4 2 Care during operation The HS1 is a high precision scientific instrument and should be handled with care during operation Failure to do so may result in permanent damage During operation ensure that there are no physical constraints on the moving stage or any...

Отзывы: