To change the Automatic Stepping settings

Double click the 

e

 DIAL KNOB at any time the unit is on and the menu will appear for 15 seconds.

Turn the 

e

 DIAL KNOB to move through down 

to the third (FEATURES) menu. Press the 

e

 

DIAL KNOB to toggle between OFF and ON or 
to change the STEPS and the STEP TIME 
settings. These settings are remembered even 
with the power off. 

EXIT MENU

 - exits this menu immediately and saves any changes. Menu will automatically exit after 

15 seconds of inactivity.

STEPS

 - pressing the knob will cycle through 2, 3, 5 and 11 then reverse direction. The endpoints of 

the steps are based on the values stored in the 

HI

 and 

LO

 EZ-CHECK outputs. 

2 steps

 will automatically switch between the values stored in the HI & LO EZ-CHECK (0 & 

100%). 

 

3 steps

 between the HI, Midpoint and LO EZ-CHECK (0, 50 & 100%). 

5 steps

 between the HI and LO EZ-CHECK in 25% increments (0, 25, 50, 75 & 100%).

11 steps

 between the HI and LO EZ-CHECK in 10% increments (0, 10, 20...80, 90 &100%).

RAMP

 continuously between the HI and LO EZ-CHECK.

STEP TIME

 - pressing the knob will cycle through 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 and 60 seconds. 

To start the Automatic Stepping

Start automatic stepping  or ramping by placing the EZ-CHECK Switch into the HI or LO position 
then press and hold the 

e

 DIAL KNOB for 6 seconds  (the word STORE will appear on the display 

after 3 seconds and continue to press the DIAL KNOB) until the word STEPPING appears on the 
display.  The word STEPPING will appear on the display anytime the selected automatic function is 
running. Stop the stepping by again pressing and holding the 

e

 DIAL KNOB for 3 seconds. 

Automatic Stepping

Storing EZ-CHECK Outputs

STORING HI and LO EZ-CHECK Outputs

Choose this function to provide a simulated RTD signal into controllers, temperature transmitters, 
indicators or any other input device that measure RTD sensors.

1)  Store your high (SPAN) output temperature by moving the EZ-CHECK switch to the 

HI

 position 

and turn the 

e

 EZ-Dial knob until the desired temperature is on the display. Press and hold the 

EZ-Dial knob until 

STORED

 appears to store the value. Release the EZ-Dial knob.

2)  Store your low (ZERO) output temperature by moving the EZ-CHECK switch to the 

LO

 position 

and turn the 

e

 EZ-Dial knob until the desired temperature is on the display. Press and hold the 

EZ-Dial knob until 

STORED

 appears to store the value. Release the EZ-Dial knob.

3) Instantly output your SPAN and ZERO temperature outputs by moving the EZ-CHECK switch 

between HI and LO. You may also select any third temperature output (such as mid-range) using 
the SET position on the EZ-CHECK switch.

           

FEATURES

> EXIT (3/3)   

      

   AUTO OFF  

        ON 

OFF

   BACKLIGHT   

   ON 

OFF

   STEPS/RAMP         2

 

3 5 11 RAMP

   STEP/RAMP TIME   5 

6 7 8 9 10 15 20 25 30 60

Содержание 311Plus

Страница 1: ...for simple hookups Carry it without worry it comes protected with a rubber boot and rugged low profile switches Easy to operate even in dark areas with the backlit display Calibrate directly in temper...

Страница 2: ...ectronics 82 East Main Street Suite 3 14 Webster NY 14580 Tel 585 872 9350 Fax 585 872 2638 sales piecal com www piecal com Magnetic Hanging Strap Optional Deluxe Hands Free Carrying Case Included Evo...

Страница 3: ...and turn the EZ DIAL knob for faster dialing Press and hold the knob for two seconds to store desired EZ Check HI LO points in SOURCE mode Continue to press and hold the knob for three more seconds to...

Страница 4: ...0 a 3850 Pt 200 a 3850 Pt 500 a 3850 Pt 1000 a 3850 Pt 100 a 3902 Pt 100 a 3916 Pt 100 a 3926 Cu 10 a 4274 Cu 50 a 4280 Ni 120 a 6720 Pt 10 a 3850 Pt 50 a 3850 Read mA Power Measure Transmitters Leak...

Страница 5: ...EXIT 4 4 AUTO OFF ON OFF BACKLIGHT ON OFF STEPS RAMP 2 3 5 11 RAMP STEP RAMP TIME 5 6 7 8 9 10 15 20 25 30 60 Double Click Menu FEATURES Double Click Menu mA DISPLAY MODE pressing the knob will cycle...

Страница 6: ...he EZ CHECK Switch into the HI or LO position then press and hold the e DIAL KNOB for 6 seconds the word STORE will appear on the display after 3 seconds and continue to press the DIAL KNOB until the...

Страница 7: ...nections are made at the top of the calibrator where the jacks are numbered for ease of use SOURCE Plug in the 2 3 or 4 wires to match the connection on the instrument being calibrated Connections REA...

Страница 8: ...made to a 4 wire sensor and the 311Plus indicates that only Wires 1 2 4 are connected There may be a loose connection or a break in wire 3 somewhere between the sensor and the 311Plus Only a calibrato...

Страница 9: ...calibrated and connect the PIE 311Plus to the inputs of the device using 2 3 or 4 wires The sensor current generated by the instrument will be indicated on the display followed by the word FIXED or PU...

Страница 10: ...Detect Transmitter Supply C 3 2 1 4 100 0 OFF OVERLOAD Double Click Menu HI SET LO SOURCE MAX READ MIN READ Push Hold to Store Step Push Turn for Fast Dialing Diagnostic RTD Milliamp Calibrator 2 3 4...

Страница 11: ...AD MIN READ Push Hold to Store Step Push Turn for Fast Dialing Diagnostic RTD Milliamp Calibrator 2 3 4 Wire Detection Loop Leak Detect Transmitter Supply mV 40 000 All RTD Ohms Connections Voltage Ou...

Страница 12: ...such as mid range using the SET position on the EZ CHECK switch The output is adjusted in 0 001 mA 0 01 increments by turning the knob e Press and turn the knob for faster dialing with 0 100 mA 1 00 i...

Страница 13: ...and disconnect the PIE 311Plus Signals above 24 mA are current limited by protection circuitry with OVERRANGE flashed on the display and the red OVERLOAD LED lit To Sensor Typical 2 Wire Transmitter D...

Страница 14: ...oose READ if your would like the mA display in percent of 4 20 milliamps PWRM is POWER MEASURE which uses the internal loop supply of the 311Plus to power up the transmitter while indicating the curre...

Страница 15: ...ster NY 14580 Tel 585 872 9350 Fax 585 872 2638 sales piecal com www piecal com Operating Instructions Typical 2 Wire Transmitter IN REF OUT 311 2 F HART 5 6 PWRM 12 523 mA Pt 100 3850 00 51 mA LEAK E...

Страница 16: ...PIE 311Plus supplies a nominal 24 volts DC at 24 mA to the 2 Wire Transmitter or loop The current passed by the transmitter will be accurately displayed by the 311Plus along with an indication of leak...

Страница 17: ...inst misconnection Over voltage protection to 60 V dc rated for 30 seconds Display High contrast graphic liquid crystal display LED backlighting for use in low lit areas Read Ohms RTD 3 Wire 4 Wire Ac...

Страница 18: ...003 mA Voltage burden 2V at 24 mA Overload Current limit protection 25 mA nominal Source mA Power Measure Two Wire Transmitters PWRM LEAK Ranges and Resolution 0 000 to 24 000 mA or 25 00 to 125 00 of...

Страница 19: ...0 842 0 to 1256 0 1256 0 to 1562 0 0 1 0 2 0 3 0 4 0 5 Pt 500 Ohm DIN IEC JIS 1989 ITS 90 1 3850 0 00385 200 0 to 90 0 120 0 to 180 0 180 0 to 450 0 450 0 to 680 0 680 0 to 850 0 0 1 0 1 0 2 0 2 0 3 3...

Страница 20: ...other expense incurred through sale or use of our equipment Under no condition shall Practical Instrument Electronics Inc be liable for any special incidental or consequential damage Additional Inform...

Отзывы: