10 Technical Data
M-230 Linear Actuators
MP102E
Version: 1.2
35
10.1.3 Limit Switch Specifications
Type
Magnetic (Hall-effect) sensor
Supply voltage
+5 V/ground
Signal output
TTL level
Signal logic
The signal level changes when passing the limit switch.
The signal logic depends on the model type:
Models with DC motor:
active high
. That means:
−
Normal motor operation:
low (0 V)
−
Limit switch reached: high (+5 V)
Models with stepper motor:
active low
. That means:
−
Normal motor operation:
high (+5 V)
−
Limit switch reached: low (0 V)
10.1.4 Reference Point Switch Specifications
Type
Magnetic (Hall-effect) sensor
Supply voltage
+5 V/GND
Signal output
TTL level
Signal logic
Index pulse when passing the reference point switch.