8 Troubleshooting
30
Version: 1.2
MP102E
M-230 Linear Actuators
Problem
Possible Causes
Solution
The mechanical
system did not stop
in time and ran into
the hard stop
Velocity is too high
(see Limit Switches
p. 11)
Limit switch is
defective
Motor controller
ignores the limit
switch signal
1. Stop the motor.
2. Command the mechanical
system away from the hard
stop.
3. Check the settings of the
motor controller for the limit
switch processing.
If the problem that occurred with your system is not listed in the table above or it
cannot be solved as described, contact our customer service department (p. 31).