8 Service
First try to identify the technical problem. Feel free to ask our support team for help. We
are pleased to assist you.
Removal of a module:
- Switch off the
phy
MOTION
™’s supply voltage
- Disconnect the supply voltage
- Cut the red seal tape and the black label tape carefully on the left and right edge of
the module/front panel which you want to remove. Don’t slide the blade between
the front panels by no means.When backfitting by our service the red seal tape is
renewed.
- Loosen the screw on top and the screw on the bottom of the module’s front plate
- Pull the card carefully by the handle.
- If you want to use the
phy
MOTION
™ after removing a module, the gap has to be
sealed with a blanking plate before power supply is reconnected and switched on.
- To send a module to phytron use ESD packaging only.