5.2.5 Option: Encoder Connection
Fig. 6: Pin assignment of the encoder
Suitable encoder types depend on the selected evaluation module (ECES01/ECAS01):
– differential incremental encoder with quadrature signals (ECAS01/ECES01)
– Absolute encoder according to the SSI standard (ECAS01/ECES01)
– EnDat encoder (ECES01)
The incremental encoder supply voltage, 5 or 5.5 V
DC
/ 200 mA max., is generated by the
controller.
Use shielded cables, twisted pair, for encoder connection. The transmission mode
includes no predection against faulty transmission values.
Wiring diagrams for the encoder types: see next page.
i
CAUTION – Possible damage!
Damage of the module by wrong connection..
- Do not exchange the 10 pin connector for limit switches with the
10 pin connector for the encoder evaluation.
- Also ensure that the encoder is configured correctly in its
programming. The connection of an incremental encoder and
parameterising for SSI can cause damage.