phytron
21
MA 1269-A007 EN
5.2.4 Limit Switch Connection
Fig. 4: Pin assignment of the limit switches
Fig. 5: Input wiring
The controller is designed for connection of up to three limit switches type PNP-NOC/NCC.
A limit switch is determined for monitoring the movement in the + direction (limit ),
the second in the – direction (limit switch –). The third switch (centre switch) for example
can be used as a reference switch. The switch type PNP NCC has the advantage that
cable breaks can be detected.
Mechanical limit switches (NCC) can also be used.
i
CAUTION – Possible damage!
Damage of the module by wrong connection.
- Do not exchange the 10 pin connector for limit switches with the
10 pin connector for the encoder evaluation.