5.2 Electrical Installation
Ensure sufficient bending radius of the cables during installation. Do not lay the cables in
tension or bend them.
We recommend labelling the mating connectors to prevent interchanging the connectors.
If all the connections are made, the last step is to plug in the power supply to the mains.
5.2.1 Connectors - Overview
Connector Number
of pins
Connector on the
module (Phoenix)
Mating connector
(Phoenix)
Mating connector
ID number
Motor
1x4
IC 2,5/4-G-5,08
IC 2,5/4-ST-5,08
10005390
Limit
switches
1x10 MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-3,5 10013217
Encoder 1x10 MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-3,5 10013217
Temperature
evaluation
2x2 MCDN1,5/2-G1-
3,5P26
FMC1,5/2-ST-3,5 10007077
The mating connector is included in delivery of the module and is usually plugged into the
module at the factory.
i
CAUTION – Possible damage!
Damage of the module by wrong connection.
- Do not exchange the 10-pin connector for limit switches with the
10-pin connector for the encoder evaluation.