PCM-061/phyCORE-i.MX7 System on Module
L-821e_2
© PHYTEC America L.L.C. 2017
41
Table 12. Technical Specifications
Dimensions:
41 mm x 50 mm
Mass:
13.01 g
6
Storage Temperature:
-40C to +90C
Operating Temperature:
-40C to +85C
Humidity:
TBD
Typ. Idling Power
Consumption:
1 W
Table 13. Recommended Operating Conditions for the Input and Output Power Domains
Symbol
Description
Conditions
Min
Typ
Max
Unit
VCC_SOM
3.3V SOM input voltage
3.14
3.3
3.46
VDC
VLDO2_1V5
1.5V Output Voltage
0.8
1.5
1.55
VDC
SW2_1V8
1.8V Output Voltage
1.5
1.8
1.85
VDC
VBAT
Battery backup for RTC
1
3
3.3
7
VDC
I
VCC_SOM
3.3V SOM operating
current
Idle in Linux with external interfaces
down/disconnected (except for Serial
RS-232 and SD card)
-
170
-
mA
Measured while testing the following
interfaces/devices simultaneously via
a python test script in Linux:
-
ETH1/ETH2 (iperf test)
-
USB1/USB2 (bandwidth test)
-
LCD Display
-
RS232
-
Mini-PCIe via StarTech Gigabit
ethernet adapter card
-
CAN via PCAN-View
-
Memtester
-
RTC
-
EEPROM
-
eMMC
-
SD
-
730
-
mA
I
VLDO2_1V5
1.5V Output load current
-
-
250
mA
I
SW2_1V8
1.8V Output load current
Not intended for directly supplying
1.8V externally. Use only to sequence
additional 1.8V power supplies.
-
-
10
mA
I
VBAT
Battery backup operating
current
Internal RTC Powered with External
RTC Disconnected
-
34.99
-
uA
External RTC Powered with Internal
RTC Disconnected
-
1.32
-
uA
Internal and External RTCs Powered
-
36.12
-
uA
6
The mass is calculated by averaging the measurements of 4x PCM-061.A4 units using a digital scale
7
The VBAT rail should never exceed the VCC_SOM supply