Pin Description
PHYTEC Messtechnik GmbH 2010 L-734e_1
13
39B
GND
-
0
Ground 0 V
40B A8_3V3
O
VDD_3V3
Address-Line
A8
41B A9_3V3
O
VDD_3V3
Address-Line
A9
42B A11_3V3
O
VDD_3V3
Address-Line
A11
43B A14_3V3
O
VDD_3V3
Address-Line
A14
44B
GND
-
0
Ground 0 V
45B A16_3V3
O
VDD_3V3
Address-Line
A16
46B A17_3V3
O
VDD_3V3
Address-Line
A17
47B A19_3V3
O
VDD_3V3
Address-Line
A19
48B A22_3V3
O
VDD_3V3
Address-Line
A22
49B
GND
-
0
Ground 0 V
50B A24_3V3
O
VDD_3V3
Address-Line
A24
51B A25_3V3
O
VDD_3V3
Address-Line
A25
52B D1
I/O
VDD_3V3
Data_Bus
D1
53B D4
I/O
VDD_3V3
Data_Bus
D4
54B
GND
-
0
Ground 0 V
55B D6
I/O
VDD_3V3
Data_Bus
D6
56B D7
I/O
VDD_3V3
Data_Bus
D7
57B D9
I/O
VDD_3V3
Data_Bus
D9
58B D12
I/O
VDD_3V3
Data_Bus
D12
59B
GND
-
0
Ground 0 V
60B D14
I/O
VDD_3V3
Data_Bus
D14
61B D15
I/O
VDD_3V3
Data_Bus
D15
62B
#X_FL_WP
I
VDD_3V3
NOR-Flash write-protect signal
63B
not connected
-
-
Pin left unconnected
64B
GND
-
0
Ground 0 V
65B
not connected
-
-
Pin left unconnected
66B
not connected
-
-
Pin left unconnected
67B
not connected
-
-
Pin left unconnected
68B
not connected
-
-
Pin left unconnected
69B
GND
-
0
Ground 0 V
70B X_FEC_RDATA1
I
VDD_3V3
Fast Ethernet Receive Data 1
71B X_FEC_RDATA3
I
VDD_3V3
Fast Ethernet Receive Data 3
72B X_FEC_MDIO
I/O
VDD_3V3
Fast
Ethernet Management Data Input/Output
73B X_FEC_CRS
I
VDD_3V3
Fast Ethernet Carrier Sense enable
74B
GND
-
0
Ground 0 V
75B X_FEC_RX_DV
I
VDD_3V3
Fast
Ethernet Receive data valid signal
76B
X_FEC_COL
I
VDD_3V3
Fast Ethernet Collision signal
77B X_FEC_TX_ERR
O
VDD_3V3
Fast Ethernet Transmit Data Error
78B
X_CSI_D7
I
VDD_3V3
Camera Sensor D7
79B
GND
-
0
Ground 0 V
Содержание phyCORE-i.MX35
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE i MX35 HARDWARE MANUAL EDITION JUNE 2010...
Страница 31: ...Jumpers PHYTEC Messtechnik GmbH 2010 L 734e_1 23 J22 J13 J4 J2 J3 Figure 7 Jumper Locations Bottom View...
Страница 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Страница 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Страница 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Страница 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Страница 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...