The phyCORE-i.MX on the Development Board
PHYTEC Messtechnik GmbH 2010 L-734e_1
57
J2
If this jumper is set to 1+2 the FETs Q13 and Q14 of the i.MX Carrier Board are
disabled. In this case there is no power supply connection from the wall charger or
POE to VIN. If J2 is set to 2+3 the power supply is connected to VIN. It is necessary to
set J2 to 1+2 if you want to supply your board with a battery.
J3
If this jumper is set to 1+2 the FETs Q15 and Q16 of the i.MX Carrier Board are
disabled. In this case there is no power supply connection from the battery connector
X21 to VIN. If J3 is set to 2+3 the battery supply is connected to VIN. It is necessary to
set J2 to 1+2 if you want to supply your board via the wall charger or POE.
J4
With this jumper you can select the backup power supply of the module. If it is set to
1+2 the backup power supply device is the goldcap C161 of the Carrier Board. If J4 is
set to 2+3 the backup power is provided by a Li-Cell at connector X20 of the Carrier
Board.
J5
Selects whether the One-Wire or the PMIC-Ready function of the i.MX35 is used.
Setting 1+2 connects the One-Wire function to the baseboard connector, setting 2+3
connects the PMIC-Ready function to the baseboard.
J6
This jumper selects where the signal X_USBH2_OC of the i.MX35 is connected to. If
the USB-Host interface of the phyMAP-i.MX35 mapper is used this jumper is set to
2+3. If the USB-Host interface of the i.MX Carrier Board is used the jumper is set to
1+2.
J7
This jumper selects where the signal X_USBH2_PWR of the i.MX35 is connected to.
If the USB-Host interface of the phyMAP-i.MX35 mapper is used this jumper is set to
2+3. If the USB-Host interface of the i.MX Carrier Board is used the jumper is set to
1+2.
J8
This jumper selects where the signal X_USBPHY2_DM of the i.MX35 is connected to.
If the USB-Host interface of the phyMAP-i.MX35 mapper is used this jumper is set to
2+3. If the USB-Host interface of the i.MX Carrier Board is used the jumper is set to
1+2.
J9
This jumper selects where the signal X_USBPHY2_DP of the i.MX35 is connected to.
If the USB-Host interface of the phyMAP-i.MX35 mapper is used this jumper is set to
2+3. If the USB-Host interface of the i.MX Carrier Board is used the jumper is set to
1+2.
J10
Jumper J10 selects whether the signal X_SD2_DATA3 is used as data3 signal of SD2
interface on the i.MX Carrier Board or if the multiplexed CAN1_TX signal is used for
the additional CAN interface on the i.MX35 mapper board. If the jumper is set to 1+2
the SD2 signal is connected to the baseboard. If the jumper is set to 2+3 the CAN
signal is used with the CAN interface on the mapper.
Содержание phyCORE-i.MX35
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE i MX35 HARDWARE MANUAL EDITION JUNE 2010...
Страница 31: ...Jumpers PHYTEC Messtechnik GmbH 2010 L 734e_1 23 J22 J13 J4 J2 J3 Figure 7 Jumper Locations Bottom View...
Страница 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Страница 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Страница 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Страница 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Страница 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...