The phyCORE-i.MX on the Development Board
PHYTEC Messtechnik GmbH 2010 L-734e_1
97
15.3.12
Complete Jumper Setting List for
phyCORE-i.MX35 on the i.MX Carrier Board
The following table contains all jumper settings that can be set on the phyCORE-i.MX Carrier Board. Also it
shows the default jumper settings for using the phyCORE-i.MX35 module with the i.MX Carrier Board.
These default jumper settings are normally done prior to delivery.
Table 33: Jumper Settings for i.MX35 Module on i.MX Carrier Board
9
J
UMPER
S
ETTING
D
ESCRIPTION
JP1
Open
Closed
RS-232 transceivers are enabled
RS-232 transceivers are disabled
JP2
Open
Closed
RS-232 auto shutdown is disabled
RS-232 auto shutdown is enabled
JP3
Open
Closed
Camera interface is managed by x_CSI_ENABLE
Camera interface is always enabled
JP4
Open
Closed
Compact Flash is in overwrite mode
Compact Flash is usable
JP5
Open
Closed
Compact-Flash is Slave
Compact-Flash is Master
JP6
Open
Closed
USBH2 transceiver Reset is not controllable
USBH2 transceiver Reset is controllable via GPIO
JP7
1+2
2+3
CAN is managed on the Carrier Board
CAN is managed on the module
JP8
1+2
2+3
CAN signals is are on the level VCC_CAN (from mapper)
CAN signals is are on the level VCC_5V
JP9
1+2
2+3
CAN is supplied via on Board 5 V Power-Supply
CAN is supplied via an external Power-Supply
JP10
1+2
2+3
CAN is managed on the Carrier Board
CAN is managed on the module
JP11
1+2
2+3
CAN is supplied via on Board Power-Supply
CAN is supplied via an external Power-Supply
JP12
Open
Closed
Only the System JTAG Controller
All core's TAPS in a single daisy chain
JP13
Open
Closed
USB Host transceiver is disabled
USB Host transceiver is enabled
JP14
Open
Closed
VCC_FUSE = 2.775 V (no FUSE programming)
VCC_FUSE = 3.3 V (use only for FUSE programming)
JP15
1+2
2+3
Camera interface supplied via on-board 3.3 V supply
Camera interface is supplied via external supply
9:
Default settings are in
bold blue
Содержание phyCORE-i.MX35
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE i MX35 HARDWARE MANUAL EDITION JUNE 2010...
Страница 31: ...Jumpers PHYTEC Messtechnik GmbH 2010 L 734e_1 23 J22 J13 J4 J2 J3 Figure 7 Jumper Locations Bottom View...
Страница 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Страница 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Страница 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Страница 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Страница 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...