4.5 Overlapped Image Acquisition Timing
which can be counted by a counter (see Section 5.1.5 for more information how to count
missed triggers). Fig. 4.11 and Fig. 4.12 shows both timing situations, when the exposure time
longer than the read out time and when the exposure time is shorter than the read out time.
E
x p o s u r e 1
R e a d O u t 1
F r a m e 1
E x p o s u r e 2
R e a d O u t 2
F r a m e 2
Figure 4.11: Overlapped Image acquisition when exposure time > read out time
E
x p o s u r e 1
R e a d O u t 1
F r a m e 1
E x p o s u r e 2
R e a d O u t 2
F r a m e 2
Figure 4.12: Overlapped Image acquisition when exposure time < read out time
MAN082 09/2019 V1.0
33 of 125
Содержание MV0 3D06 Series
Страница 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Страница 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Страница 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Страница 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Страница 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Страница 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Страница 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Страница 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Страница 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Страница 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Страница 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Страница 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Страница 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...
Страница 125: ...D Document Revision History Revision Date Change 1 0 September 2019 First version MAN082 09 2019 V1 0 125 of 125...