4.3 Frame Control
F
r a m e 1
. . . .
F r a m e N
A
c q u i s i t i o n A c t i v e
A
c q u i s i t i o n S t a r t
T r i g g e r 1
A c q u i s i t i o n E n d
T r i g g e r 1
F r a m e
T r i g g e r
W a i t
F r a m e
T r i g g e r
W a i t
A c q u s i t i o n
T r i g g e r
W a i t
A c q u i s i t i o n S t o p ( )
A c q u s i t i o n
T r i g g e r
W a i t
A c q u i s i t i o n S t a r t ( )
F r a m e B u r s t S t a r t
T r i g g e r 1
F r a m e B u r s t E n d
T r i g g e r 1
( o p t i o n a l )
F r a m e
A c t i v e
F r a m e S t a r t
T r i g g e r 1
F r a m e
A c t i v e
F r a m e
T r i g g e r
W a i t
F r a m e 1
A c q u i s i t i o n S t a r t T r i g g e r M o d e = O n
A c q u i s i t i o n E n d T r i g g e r M o d e = O n
F r a m e S t a r t T r i g g e r M o d e = O n
F r a m e B u r s t S t a r t T r i g g e r M o d e = O n
E x p o s u r e M o d e = T i m e d
Figure 4.7: Triggered Acquisition of a Burst of Frame and of a single Frame
4.3.4
Frame Control Output Signals
The frame control block has the following output signals:
Frame Trigger Wait
An asserted frame trigger wait indicates, that the frame control is waiting
for a frame start trigger (see Section 4.3.1), frame burst start trigger (see Section 4.3.2) or
an exposure start trigger (see Section 4.4.2).
Frame Active
An asserted frame active signal indicates, that one or more frames are being
captured.
Frame Start
The frame start is an event, which is generated, when a new frame starts.
Frame End
The frame end is an event, which is generated, when a frame is finished.
Frame Burst Start
The frame burst start is an event, which is generated, when a new burst of
frame starts.
Frame Burst End
The frame burst end is an event, which is generated, when a burst of frame is
finished.
Frame Trigger
The frame trigger is an event, which is generated, when a frame is started by a
frame start trigger (see Section 4.3.1), by a frame burst start trigger (see Section 4.3.2) or
by an exposure start trigger (see Section 4.4.2).
Frame trigger wait and frame active status signal are routed to the I/O control block and can
there be selected for output on the physical output line or on one of the available leds. Frame
start, frame end and frame trigger event can be used to trigger or to control other function in
the camera, like counter and timer.
MAN082 09/2019 V1.0
29 of 125
Содержание MV0 3D06 Series
Страница 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Страница 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Страница 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Страница 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Страница 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Страница 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Страница 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Страница 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Страница 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Страница 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Страница 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Страница 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Страница 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...
Страница 125: ...D Document Revision History Revision Date Change 1 0 September 2019 First version MAN082 09 2019 V1 0 125 of 125...