Thank you for selecting the Photogenic Professional 
Skylighter CFF series.  The CFF series incorporates the 
newest electronic components, lamps, reflectors, and diffusion 
panels providing improved lighting distribution and control.  
These products are built for the demanding operational needs 
of the professional photographer and it is our expectation that 
your Skylighter CFF will provide you with years of 
dependable service.   

 
 

INTRODUCTION 

The Skylighter CFF series are an extremely diffused light head 
and require an external power supply.  They have one, two, or 
four professional, plug-in, linear flashtubes, and one, two, or 
four non-adjustable, linear, fluorescent modeling lamps.  The 
Skylighter CFF series are stand mounted on a strong, rotating 
yoke, but may be ceiling hung, as required. 
 
Before using your new Skylighter CFF for the first time, 
please read this manual carefully and acquaint yourself with 
the controls and features.  In this way, you can quickly get the 
greatest benefit from your new unit and maintain an efficient 
and safe operation. 

 

SAFETY PRECAUTIONS 

 
Despite the measures that have been taken to make electronic flash equipment safe, 
it must be recognized that high voltages and high temperatures do exist within the 
power supply / lighting unit.  Certain precautions must be observed in handling the 
unit. Contact with internal high voltage may result in severe injury or death. 

Содержание Skylighter CFF2

Страница 1: ...Skylighter Brand Fluorescent Strobe Lighting Operator s Manual Skylighter CFF2 Skylighter CFF4 Skylighter CFF8...

Страница 2: ...two or four professional plug in linear flashtubes and one two or four non adjustable linear fluorescent modeling lamps The Skylighter CFF series are stand mounted on a strong rotating yoke but may be...

Страница 3: ...ssembled and all parts accounted for After unpacking all parts should be examined for any damage which may have been caused by rough handling during shipment If any damage is detected contact the deli...

Страница 4: ...to the circular input connector located on the back of the Skylighter and connect the other end to the purchased PowerLight power supply See PowerLight instructions for installation and operation Powe...

Страница 5: ...supply fuse internal 5 amp power supply fuse internal Packaging Aluminum case Aluminum case Aluminum case Weight 11 lbs 16 lbs 28 lbs Dimensions Box only 23 W x 9 H With yoke 26 W x 14 H Box only 23 W...

Страница 6: ...eter reading The other numbers are the relative change in readings with meter position always at grid crossings Minolta Flash Meter V time 1 125 sec iso 125 CFF2 at 5 ft from wall Fluorescent lamp onl...

Страница 7: ...0 3 0 7 0 8 1 0 1 1 0 9 1 0 0 5 0 6 0 1 0 2 0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 2 0 5 0 6 0 9 1 0 0 8 1 0 0 5 0 6 0 0 0 1 0 0 0 0 4 0 4 1 4 9 0 1 0 0 0 0 0 1 0 5 0 6 0 8 1 0 0 8 0 9 0 6 0 7 0 1 0 2 0 0 0 0...

Страница 8: ...1 1 0 9 0 5 0 4 0 5 0 4 0 5 0 9 1 1 1 1 0 8 0 3 0 2 0 3 0 2 0 3 0 8 1 1 1 0 0 6 0 2 0 0 0 1 0 0 0 2 0 6 1 0 0 9 0 6 0 1 0 0 11 8 8 0 7 5 6 6 0 0 0 1 0 6 0 9 0 8 0 6 0 1 0 0 0 1 0 0 0 1 0 6 0 8 1 0 0 8...

Страница 9: ...1 0 0 7 0 6 0 6 0 6 0 7 1 0 1 1 1 0 0 8 0 5 0 4 0 3 0 4 0 5 0 8 1 0 0 9 0 6 0 3 0 1 0 0 0 1 0 3 0 6 0 9 0 7 0 5 0 3 0 1 1 4 2 0 1 0 3 0 5 0 7 0 9 0 6 0 3 0 1 0 1 0 1 0 3 0 6 0 9 1 0 0 8 0 5 0 3 0 3 0...

Страница 10: ...0 9 0 6 0 6 0 6 0 6 0 6 0 9 1 0 0 9 0 7 0 5 0 3 0 3 0 3 0 5 0 7 0 9 0 8 0 6 0 2 0 1 0 1 0 1 0 3 0 6 0 8 0 8 0 6 0 1 0 0 11 7 8 0 6 5 6 5 4 0 4 2 8 1 2 0 0 0 0 0 1 0 6 0 8 0 8 0 6 0 2 0 0 0 0 0 0 0 2 0...

Страница 11: ...CFF4 at 10 ft from wall Fluorescent only and Flash 31 125 1000ws 0 3 0 1 0 3 0 1 0 1 0 1 0 1 0 0 0 1 0 3 0 2 0 1 0 0 8 0 1 2 0 8 1 0 6 0 7 9 0 0 0 1 0 2 0 3 0 1 0 1 0 1 0 2 0 2 0 2 0 5 0 2 0 5...

Страница 12: ...ft from wall Fluorescent lamp and Flash 31 63 125 250 500 1000ws 0 9 0 5 0 9 0 5 0 3 0 5 0 1 0 1 0 1 0 9 0 5 0 2 0 0 11 4 8 0 3 5 6 2 4 0 1 2 0 9 2 0 3 2 0 0 0 0 0 2 0 5 0 9 0 1 0 1 0 1 0 5 0 3 0 5 0...

Страница 13: ...CFF8 at 10 ft from wall Fluorescent lamp and Flash 31 125 250 1000ws 0 1 0 0 0 0 0 3 0 1 0 0 0 0 5 6 8 2 8 6 2 0 6 1 0 9 1 0 5 0 0 0 0 0 1 0 3 0 0 0 0 0 1...

Страница 14: ...nd PowerLight generator and discharge the stored energy by pressing the test button Unplug the cable connecting the Skylighter to the PowerLight generator It is now safe to change the lamps in the Sky...

Страница 15: ...repair or replace any PL2 series light that is deemed to be defective This warranty does not cover damages caused by shipping product abuse or use other than the intended photographic applications An...

Страница 16: ...Photogenic Professional Lighting 1268 Humbracht Circle Bartlett Illinois 60103 www Photogenicpro com Telephone 630 830 2500 Fax 630 830 2525 MANUAL PART NO 016341 00V3 05...