Toll-Free 1-800-533-7533

4.   Remove the condensate hose and the one screw 

attaching the pump bracket to the compressor support

5.   Replace the pump, hose, wiring, bolts, and housing in 

the reverse order

5.6 Float Safety Switch

The float safety switch activates when the water rises too 

high in the condensate reservoir. The float safety switch 

turns off the compressor until the water level lowers and 

disengages the switch.

To replace the float safety switch
1.   Unplug the dehumidifier
2.   Remove the front housing
3.   Unplug the float safety switch wires from the wire 

harness

4.   Remove the one screw attaching the pump and float 

switch bracket to the compressor support

5.   Remove the pump from the reservoir and slide out the 

float switch from under the compressor support

6.   Replace the float, pump, wiring, bolts and housing in the 

reverse order

6 Options & Accessories

4025568  

Air Filter, Pleated 12” x 12” x 1” MERV-11

4024750  

Intake Flex Duct 12” x 25”  

 

Metallize Polyester

4024935  

Lay-Flat Duct 10” Round x 250’ Roll

To order, contact Therma-Stor LLC at 1-800-533-7533.

5.3 Air Mover

The motorized impeller has a PSC motor and internal thermal 

overload protection. If defective, the complete assembly must 

be replaced.
1.   Unplug power cord
2.   Remove the four screws attaching the bottom plate to 

the lower housing

3.   Disconnect the impeller leads
4.   Remove the four screws holding the impeller to the 

bottom plate

5.   Reassemble the new impeller using the above procedure 

in reverse

5.4 Thermistor

The defrost thermistor is 

attached to the refrigerant 

suction line between the 

accumulator and the 

evaporator.
To replace thermistor:
1.   Unplug the dehumidifier
2.   Remove the front housing
3.   Cut cable ties and remove 

insulation and aluminum tape.

4.   Remove control panel
5.   Unthread thermistor from control housing grommet
6.   Detach thermistor from control board jumper
7.   Reassemble thermistor and dehumidifier using the above 

procedure in reverse

5.5 Condensate Pump

The internal condensate pump removes water that collects in 

the reservoir.
To replace the condensate pump:
1.   Unplug the unit
2.   Remove the front housing
3.   Unplug the pump wires from the wire harness

Figure 8: Picture of the float safety switch.

Figure 6: Thermistor attached

to the refrigerant line.

Figure 7: Picture of pump and float switch brackets screw.

Содержание R175

Страница 1: ...idifiers of equal size Energy Efficiency Removes 92 pints at AHAM while drawing only 6 3 amps Patented Bypass Technology 230 CFM More processed air speeds drying and provides superior static pressure for ducting More Grain Depression Drier from an LGR gets your jobs drier quicker Focused Airflow Patent focused outlet directs air downward across the wet surface Multiple Ducting Options 12 intake 10...

Страница 2: ...ar 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 33 high x 20 wide x 20 deep Weight 105 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and doors are closed to the outside and seal off the wet area fr...

Страница 3: ...reases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will show the accumulated hours Press the POWER button again to turn the dehumidifier off The display will also power off 3 7 PURGE Button During normal operation ...

Страница 4: ... drain 2 Plug in the unit but do not turn it on 3 Remove the air filter Slowly pour a pint of the chemical through the top so that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R175 with its high pressure refrigerant system and high ...

Страница 5: ...gure 5 Refrigeration system Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air f...

Страница 6: ...ma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom plate to the lower housing 3 Disconnect the impeller leads 4 Remove the four screws holding the impeller to the bottom plate 5 Reassemble the new impeller usi...

Страница 7: ...U 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL 8 RUN CAPACITOR RUN CAPACITOR BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 9 Wiring diagram 7 Wiring Diagram ...

Страница 8: ...33 long 1 4024916 12 Coupling Body 1 4 Tube 1 4026306 13 Coupling Insert 1 4 Tube 1 4026986 14 Cord 1 4032297 15 Control Board 1 4026763 16 Capacitor Compressor 45 μF 1 4033032 05 17 Capacitor Impeller 7 5 μF 1 4033031 04 18 Thermistor 1 4031279 Items listed are not shown Description Qty Part No Compressor 1 4029168 Evaporator Coil 1 4028234 Condenser Coil 1 4028235 Accumulator 1 4028297 Condensat...

Страница 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R175 Dehumidifier part is repaired...

Отзывы: