background image

 

EG-Konformitätserklärung 

 

EU Declaration of Conformity

 

Nach Anhang IV der EMV-Richtlinie 2014/30/EU

 

 

In compliance with Appendix IV of the EMC-Directive 
2014/30/EU

 

Nach Anhang IV der EU-Niederspannungsrichtlinie 
2014/35/EU 

 

In compliance with Appendix IV of the LVD-Directive 
2014/35/EU 

Nach Anhang VI der RoHS-Richtlinie 2011/65/EU  
(inkl. Delegierte Richtlinie (EU) 2015/863) 

 

In compliance with Appendix VI of the EU RoHS 
Directive 2011/65/EU 
(incl. Commission delegated Directive (EU) 2015/863) 

Der Hersteller 

 

The manufacturer 

DewertOkin GmbH 

Weststraße 1 

32278 Kirchlengern 

Deutschland - 

Germany 

erklärt hiermit, dass das Produkt 

 

declares that the following product 

                                       MEGAMAT XSZ 

 

                                    MEGAMAT XS(n)
mit DewertOkinSteuerung     /     with DewertOkin Control unit 

1)

 

die Anforderungen folgender EG-Richtlinien erfüllt: 

 

meets the requirements of the following EU directives: 

Richtlinie über elektromagnetische Verträglichkeit 

2014/30/EU

 

 

Electromagnetic Compatibility Directive 2014/30/EU

 

Niederspannungsrichtlinie 2014/35/EU

 

 

Low Voltage Directive 2014/35/EU

 

DELEGIERTE  RICHTLINIE  (EU)  2015/863  DER 

KOMMISSION vom 31. März 2015 zur Änderung von 

Anhang  II  der  Richtlinie  2011/65/EU  des  Euro-

päischen Parlaments und des Rates hinsichtlich der 

Liste der Stoffe, die Beschränkungen unterliegen.

 

 

COMMISSION  DELEGATED  DIRECTIVE  (EU) 

2015/863  of  31  March  2015  amending  Annex  II  to 

Directive  2011/65/EU  of  the  European  Parliament 

and  of  the  Council  as r egards  the  list  of  restricted 

substances.

 

Angewendete Normen 

 

Applied standards: 

  EN 60335-1:2012/A11:2014

 

  EN 55014-1:2006/A1:2009/A2:2011

 

  EN 55014-2:1997/A1:2001/A2:2008

 

  EN 61000-3-2:2014

 

  EN 61000-3-3:2013

 

  EN 62233:2008

  

Konstruktive Änderungen, die Auswirkungen auf die in 
der Montageanleitung angegebenen technischen Daten 
und den bestimmungsgemäßen Gebrauch haben, das 
Produkt also wesentlich verändern, machen diese 
Konformitätserklärung ungültig! 

 

 

This declaration of conformity is no longer valid if 
constructional changes are made which significantly 
change the drive system (i.e., which influence the 
technical specifications found in the instructions or the 
intended use)! 

 

 

 

 

Kirchlengern, Germany 25 November 2019

  

 

Dr.-Ing. Josef G. Groß

 

 

 

 

 

 

 

 

 

 

Geschäftsführer / Managing Director 

 

1) 

(n) steht für/

stands for

 1 – 5

 

Содержание DewertOkin MEGAMAT XS

Страница 1: ...MEGAMAT XS Installation Instructions Translation of the original installation instructions...

Страница 2: ......

Страница 3: ...ating instruction manual for the entire end product These instructions are only intended to be used by the end product manufacturer They should not be given to the operator of the end product The fact...

Страница 4: ...nstruction of the MEGAMAT XS drive has been inspected by the German T V S D Product Service Inspection Authority T V S D Product Service also monitors the production of the MEGAMAT XS The official Ger...

Страница 5: ...9 2 1 Proper and intended usage 9 2 2 Safety notices within the installation instruction and the operating instructions for the entire machine 10 2 3 Selection and qualification of personnel 10 2 4 No...

Страница 6: ...of Contents MEGAMAT XS 6 73115 4 0 10 Disposal 26 10 1 Packaging material 26 10 2 Drive components 26 Declaration of incorporation installation 27 EU Declaration of Conformity 28 Additional informati...

Страница 7: ...lation and connection procedures will help to minimize the risk of accident and injury and damage to the drive system or the end product These installation instructions have been written with due care...

Страница 8: ...ety notice explanations WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoide...

Страница 9: ...t WARNING The MEGAMAT XS drive should not be used in any environment where combustible or explosive gases or vapours e g anaes thesiology may be present with pulling or pushing forces that exceed thos...

Страница 10: ...roperly qualified person should be found for this task 2 4 Notice on safety during operations Basic safety rules must be followed in order to ensure that the end product can be continually op erated i...

Страница 11: ...late The ratings plate shown is an example the specifications for your drive may differ from this illus tration Figure 2 Ratings plate example MEGAMAT XSZ Model name xxxxx Article number 24 29V Input...

Страница 12: ...set and control units as needed Make sure that you switch off the electricity before connecting any components connect while in a voltage free state DewertOkin has separate system instruction manuals...

Страница 13: ...performance the mounting of the stroke pipe We reserve the right to make unannounced technical changes in the course of our continual product improvement process 4 1 Components The main components of...

Страница 14: ...these two versions are shown in the following illustrations CAUTION If the stroke pipe is unattached then the end product must be designed to prevent the stroke pipe from coming out during operations...

Страница 15: ...Protection degree IPX4 IPX6 Stroke 350 mm Colours Refer to sales brochure Dimensions and weight Length x width x height Min 168 mm x 146 mm x 62 mm Weight Approx 1 5 kg depending on version Ambient c...

Страница 16: ...Technical specifications MEGAMAT XS 16 73115 4 0 Figure 6 Dimensions of MEGAMAT XS drive in mm minimum installation dimension 145 mm Min 168 146 62 145...

Страница 17: ...elp pre vent shear stress Do not position the drive at a slanted angle when installing it in the end product A slanted angle between the intended direction of movement of the end product and the drive...

Страница 18: ...chnical or cost reasons you choose not to use end stops then we strongly recommend the use of an additional safety limit switch whenever the DewertOkin drive is being used for at risk functions A safe...

Страница 19: ...or securing the drive on the stroke pipe side C Head of stroke pipe D Mounting bolt E Gear clevis F Bracket for securing the drive on the motor side In the following example installation of the MEGAMA...

Страница 20: ...ed out If the hand switch will be used to control two drives you must first connect both drives electri cally to each other for example over a control unit Then you can connect the handset 6 2 2 Elect...

Страница 21: ...should be connected or disconnected only when the mains power cord and the battery plug when present are unplugged Certain details may change because of technical changes 1 Move your product into a po...

Страница 22: ...ration is an operational mode where the drive must pause after a specified maximum period of operation power on time This protects the drive from overheating Extreme overheating can cause a malfunctio...

Страница 23: ...ed nut CAUTION You should never screw the stroke pipe into the drive A stroke pipe that has been screwed into the drive can result in fatigue fractures CAUTION The stroke pipe may only be turned one h...

Страница 24: ...drive system is defective Please contact your supplier or sales agent The drive is suddenly not capable of move ment Possibly the thermal circuit breaker on the transformer has been triggered or is d...

Страница 25: ...tions are firmly seated and correctly positioned At least every six months Periodic visual inspection for cable damage Check the connecting cables for pinching or shearing Also check the strain relief...

Страница 26: ...2008 98 EC Waste Framework Directive WFD as of 12 12 2008 10 2 Drive components The MEGAMAT XS drive consists of electronic components cables and metal and plastic parts You should observe all corresp...

Страница 27: ...incomplete machine after you have confirmed that the end product into which this machine will be installed complies with the Machinery Directive 2006 42 EC Der Hersteller verpflichtet sich die speziel...

Страница 28: ...oltage Directive 2014 35 EU DELEGIERTE RICHTLINIE EU 2015 863 DER KOMMISSION vom 31 M rz 2015 zur nderung von Anhang II der Richtlinie 2011 65 EU des Euro p ischen Parlaments und des Rates hinsichtlic...

Страница 29: ...1 Section 7 1 Labelling general IEC EN60601 1 Section 7 2 Labelling inscriptions IEC EN60601 1 Abschnitt 8 Protection against electrical danger IEC EN60601 1 Section 11 1 Overheating protection IEC EN...

Страница 30: ...DewertOkin GmbH Weststrasse 1 Kirchlengern 32278 Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de ID No 73115...

Отзывы: