Installation
MEGAMAT XS
20
73115 4.0
CAUTION
You should never screw the stroke pipe into the drive. A stroke pipe that has been
screwed into the drive can result in fatigue fractures.
5
If the stroke pipe clevis (
C
) does not align exactly with the gear clevis (
E
), the stroke pipe may
be unscrewed out of the drive by no more than a half turn.
CAUTION
The stroke pipe may only be turned one half rotation out of the drive. Do not rotate the
stroke pipe further out. An over-rotation can lead to unsafe operations.
6
Attach the stroke pipe (
C
) using a mounting bolt (
D
) to the fitting (
B
).
7
Secure the mounting bolt (
D
) with the safety clip (
A
).
8
Now connect the drive to the control unit or the double drive. Ensure that the electrical connec-
tion cable cannot be pulled out.
If the hand switch will be used to control two drives, you must first connect both drives electri-
cally to each other (for example, over a control unit). Then you can connect the handset.
6.2.2
Electrical connection
CAUTION
Electrical components should be connected or disconnected only when the mains
power cord and the battery plug (when present) are unplugged.
WARNING
Only the following personnel are qualified to work on the power cord or to replace the
power cord:
•
someone who has completed training in electronic motor assembly,
•
someone with equivalent qualifications, or
•
someone who has successfully completed the appropriate DewertOkin training pro-
gram.
You should only work on the power cord when you are qualified to do so. Otherwise, a
properly qualified person should be found for this task.
NOTICE
There is a delay after the supply voltage is applied before the device actually turns on.
Wait at least 15 seconds before initial commissioning.