background image

 

 

EG-Konformitätserklärung  

(Ausführung 2,4GHz) 

 

EU Declaration of Conformity  

(Version 2.4GHz) 

Nach Anhang VI der RED-Richtlinie 2014/53/EU

 

 

In compliance with Appendix VI of the RED-Directive  
2014/53/EU

 

Nach Anhang VI der RoHS-Richtlinie 2011/65/EU  
(inkl. Delegierte Richtlinie (EU) 2015/863) 

 

In compliance with Appendix VI of the EU RoHS 
Directive 2011/65/EU 
(incl. Commission delegated Directive (EU) 2015/863) 

Der Hersteller 

 

The manufacturer

:

 

DewertOkin GmbH 

Weststraße 1 

32278 Kirchlengern 

Deutschland - 

Germany 

erklärt hiermit, dass das Produkt 

 

declares that the following product 

CONTROL UNIT 

HE

-3

00

 

die Anforderungen folgender EG-Richtlinien erfüllt: 

 

meets the requirements of the following EU directives: 

Richtlinie 2014/53 über die Harmonisierung der 

Rechtsvorschriften der Mitgliedstaaten über die 

Bereitstellung von Funkanlagen auf dem Markt

 

 

RED Directive 2014/53/EU 

DELEGIERTE  RICHTLINIE  (EU)  2015/863  DER 

KOMMISSION  vom  31.  März  2015  zur  Änderung 

von Anhang II der Richtlinie 2011/65/EU des Euro-

päischen  Parlaments  und  des  Rates  hinsichtlich 

der  Liste  der  Stoffe,  die  Beschränkungen 

unterliegen.

 

 

COMMISSION  DELEGATED  DIRECTIVE  (EU) 
2015/863 of 31 March 2015 amending Annex II to 
Directive 2011/65/EU of the European Parliament 
and  of  the  Council  as  regards  the  list  of 
restricted substances.
 

Angewendete Normen 

 

Applied standards: 

  EN 60335-1:2012/A11:2014 

  EN 55014-1:2006/A1:2009/A2:2011 

  EN 55014-2:1997/A1:2001/A2:2008 

  EN 61000-3-2:2014 

  EN 61000-3-3:2013 

  EN 62233:2008  

  EN 62479:2010  

  ETSI EN 300440 V2.1.1 

  Draft ETSI EN 301489-1 V2.2.0 

  Final Draft ETSI EN 301489-3 V2.1.1 

Konstruktive  Änderungen,  die  Auswirkungen  auf  die 
in  der  Montageanleitung  angegebenen  technischen 
Daten  und  den  bestimmungsgemäßen  Gebrauch 
haben,  das  Produkt  also  wesentlich  verändern, 
machen diese Konformitätserklärung ungültig! 

 

 

This  declaration  of  conformity  is  no  longer  valid  if 
constructional  changes  are  made  which  significantly 
change  the  drive  system  (i.e.,  which  influence  the 
technical  specifications  found  in  the  instructions  or 
the intended use)!

 

 

 

Kirchlengern, Germany 25. November 2019

 

 

Dr.-Ing. Josef G. Groß

 

 

 

 

 

 

 

 

 

 

Geschäftsführer / Managing Director

 

Содержание Dewert Okin HE-300 SMPS

Страница 1: ...CONTROL UNIT HE 300 Installation Instructions Translation of the original installation instructions...

Страница 2: ......

Страница 3: ...s when creating the end product manual The warning and danger notices are best suited for use in the end product s manual However it is not sufficient to simply follow these notices You should also ca...

Страница 4: ...ation of personnel 7 2 3 Ratings plate 8 3 Possible combinations 9 4 Description 10 4 1 Components 10 5 Technical specifications 11 6 Installation 13 6 1 Safety notices to observe during installation...

Страница 5: ...n procedures to minimize the risk of accident and injury and damage to the CONTROL UNIT HE 300 or the end product These installation instructions have been written with due care and attention However...

Страница 6: ...the users of your end product The CONTROL UNIT HE 300 should not be used in any environment where combustible or explosive gases or vapours e g anaesthesiology may be present in the proximity of open...

Страница 7: ...only install the CONTROL UNIT HE 300 when you are qualified to do so Otherwise a properly qualified person should be found for this task 2 2 1 Electrical safety CAUTION Electric shock Be careful there...

Страница 8: ...ate for the CONTROL UNIT HE 300 example HE 300 Model name xxxxx Article number 24 29V Input voltage Max 5 00 A Current consumption Duty cycle 2 min ON 18 min OFF Mode of operation 2 40 GHz Radio frequ...

Страница 9: ...hat have been approved by DewertOkin A tailored system consists of the combination of control unit single drive massage motor accesso ries and hand held remote DewertOkin has separate system instructi...

Страница 10: ...the CONTROL UNIT HE 300 has a connection for an external DewertOkin power supply as well as connections for single drives massage motors and various accessories refer to Chapter 3 Possible combinatio...

Страница 11: ...rom diodes Laser class 1 EN 60825 1 1994 Dimensions and weight Length x width x height 299 mm x 86 mm x 43 mm Weight Approx 500 g Ambient conditions for operation storage and transport Transport stora...

Страница 12: ...Technical specifications CONTROL UNIT HE 300 12 79822 Figure 3 Dimensions of the CONTROL UNIT HE 300 top view in mm Figure 4 Dimensions of the CONTROL UNIT HE 300 side view in mm 43 299 86...

Страница 13: ...in the Safety notices to observe during installation section 6 2 1 Mounting the CONTROL UNIT HE 300 to the end product Four screws should be used at the four mounting points to attach the CONTROL UNIT...

Страница 14: ...that they project slightly out of your end product 3 Put the CONTROL UNIT HE 300 onto the four screws at the four mounting points 4 Pull the CONTROL UNIT HE 300 gently in the direction shown by the a...

Страница 15: ...such as pulling pushing or bending will be put on the cables and the cables cannot be damaged in any way Fasten all cables especially the connecting cables to the end product using sufficient kink pre...

Страница 16: ...and are not for typical users of the end product 7 1 General information You should only connect drives massage motors and accessories from DewertOkin to the CONTROL UNIT HE 300 Only DewertOkin compon...

Страница 17: ...ructions carefully You could be injured by fire or electrical shock if you do not follow these assembly instructions Emergency shut off of a connected drive or CONTROL UNIT HE 300 In an emergency disc...

Страница 18: ...not been programmed with the teach in Carry out the teach in routine for the hand held remote The hand held remote batteries are empty Replace the batteries The drives or mas sage motors are sud denl...

Страница 19: ...heck that all electrical cables and connections are firmly seated and correctly positioned At least every six months Look over the cables for any signs of damage Check the connecting cables for pinchi...

Страница 20: ...98 EC Waste Framework Directive WFD as of 12 12 2008 10 2 Components in the control unit The CONTROL UNIT HE 300 consists of electronic components cables and metal and plastic parts You should observ...

Страница 21: ...35 EU Low Voltage Directive 2014 35 EU DELEGIERTE RICHTLINIE EU 2015 863 DER KOMMISSION vom 31 M rz 2015 zur nderung von Anhang II der Richtlinie 2011 65 EU des Euro p ischen Parlaments und des Rates...

Страница 22: ...der Richtlinie 2011 65 EU des Euro p ischen Parlaments und des Rates hinsichtlich der Liste der Stoffe die Beschr nkungen unterliegen COMMISSION DELEGATED DIRECTIVE EU 2015 863 of 31 March 2015 amendi...

Страница 23: ...DewertOkin GmbH Weststrasse 1 Kirchlengern 32278 Germany Tel 49 0 5223 979 0 Fax 49 0 522375182 http www dewertokin de Info dewertokin de ID No 79822...

Отзывы: