Technical data and ordering data
107065_en_01
PHOENIX CONTACT
83
Ethernet interfaces
Properties of the RJ45 ports
Number
Up to 8 with auto crossing and auto negotiation
Connection format
8-pos. RJ45 socket on the switch
Connection medium
Twisted pair cable
Cable impedance
100 ohms
Transmission speed
10/100/1000 Mbps
Maximum network segment expansion
100 m
Properties of the fiberglass ports
Number
Up to 2
Connection format
Gigabit SFP format
Connection medium
Fiberglass
Connecting plug
LC format (SFP module)
Transmission speed
100/1000 Mbps (depending on the SFP module used)
Maximum network segment expansion
Depends on the SFP module/fiber type used
Fiber type
Depends on the SFP module used
Laser protection class
1
Wavelength
850/1310/1550 nm (depending on the device/SFP module used)
Properties of the combo ports
Number
Up to 2
Transmission speed
100/1000 Mbps
Wavelength
Depends on the SFP module used
Maximum transmission length
Depends on the SFP module used
Mechanical tests
Shock testing according to IEC 60068-2-27
Operation: 30g,
half-sine shock pulse
Vibration resistance according to IEC 60068-2-6
Operation/storage/transport: 5g, 10 Hz - 150 Hz
Free fall according to IEC 60068-2-32
1 m
Conformance with EMC Directives
Developed according to IEC 61000-6-2
Noise emission according to EN 55022: 1998
+ A1: 2000 + A2: 2003 (interference voltage)
Class A (industrial applications)
Noise emission according to EN 55011: 1998
+ A1: 1999 + A2: 2002 (electromagnetic interference)
Class A (industrial applications)
Noise immunity according to EN 61000-4-2 (IEC 1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion B
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-3 (IEC 1000-4-3)
(electromagnetic fields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Содержание FL SWITCH 2005
Страница 1: ...User manual FL SWITCH 2000 Order No...
Страница 62: ...FL SWITCH 2000 62 PHOENIX CONTACT 107065_en_01...
Страница 68: ...FL SWITCH 2000 68 PHOENIX CONTACT 107065_en_01...
Страница 87: ...Technical data and ordering data 107065_en_01 PHOENIX CONTACT 87 49 5281 9 462888...
Страница 88: ...FL SWITCH 2000 88 PHOENIX CONTACT 107065_en_01...
Страница 92: ...FL SWITCH 2000 92 PHOENIX CONTACT 107065_en_01...
Страница 94: ...FL SWITCH 2000 94 PHOENIX CONTACT 107065_en_01...
Страница 98: ...FL SWITCH 2000 98 PHOENIX CONTACT 107065_en_01...