Description of the controllers
107708_en_08
PHOENIX CONTACT
3.15.1
Ethernet
The Ethernet network is connected via RJ45 sockets.
3.16
Supply connector
Figure 3-19
Terminal points for the supply voltage (communications voltage U
L
)
Terminal point
assignment
Key:
•
Use an Ethernet cable that complies with at least CAT5 of IEEE 802.3.
•
Observe the bending radii of the Ethernet cables used.
a1
a2
b1
b2
a1
a
2
b1
b
2
Table 3-3
Terminal point assignment of the supply connector
Terminal point
Color
Assignment
a1, a2
Red
24 V DC (U
L
)
b1, b2
Blue
GND
U
L
Communications voltage feed-in (bridged internally)
GND
Supply voltage reference potential (bridged internally)