Box number
This switch (BOX) informs the circuit about the accessory number when
two boxes are designated to the same camera input of the system
monitor. A maximum of two alarm/action boxes can be designated to
one camera input.
Switch 1 (BOX)
position
description
1
first box which is designated to the camera input set
by CAMERA #
2
second box which is designated to the camera input
set by CAMERA #
Tamper switch active
On the circuit board a tamper switch secures the box. When opening the
box this switch triggers an alarm on the monitor. To suppress a
continuous alarm message while servicing the system, the tamper-switch
override is set in the
OFF
position.
Caution:
Don't forget to
reactivate
the tamper switch by switching the override to
the
TAMPER
position!
Last in line switch
Set this switch to
Y
(es) if this alarm/action box is the last accessory box
in the system cable (seen from the system monitor).
15