Technical specifications
Power supply
through the system cable (24V
DC
)
Contact ratings action relay
30V, 5A AC/DC
Alarm input trigger threshold
> 150
Ω
(N.C. input)
< 150
Ω
(N.O. input)
System connectors
RJ11E modular ('telephone' connectors)
System cable
4-wire dual twisted-pair telephone cable
PIR angle of sight
•
horizontal
110
°
•
vertical
20
°
Dimensions
•
without PIR
119 x 77 x 40 mm
Ambient conditions
ammonia resistant
Temperature
•
operating
+10...+45
°
C
•
storage
-25...+70
°
C
Humidity
•
operating
20...90%RH
•
storage
20...99%RH
Specifications may change without notice.