Adjust lens position (0°, -5° or -10°) according to desired maximum
sensor range (see table below).
Remark:
Do not use pos5° or +10° as they do not apply to this PIR.
Sensor height
Maximum sensor range (m) / Lens position (°)
0°
-5°
-10°
2.5 m
14 m
12.5 m
11 m
2.0 m
12 m
10.5 m
9.5 m
1.5 m
10 m
8.5 m
8 m
7
Make the interconnections between the PIR and the alarm/action box
with the cable supplied (see figure below).
1
Terminal block (for interconnection with alarm/action box)
2
Lens position (sensor range adjustment)
3
Jumper (walk test LED activated/deactivated)
4
Tamper switch
5
PYRO sensor
6
Jumper (1, 2 or 3 pulse count)
7
Locking latch
8
Terminal block in alarm/action box
CL 76610006_004.AI
5
8
7
6
2
1
4
3
GND
NC
+12V
+10
+5
0
-5
-10
+
_
NC
PIR
9
g