Self-Tests
Running Parameter Tests
The luminaire is capable of running self-tests by using the
Test
menu functions.
When running tests on multiple luminaires, a DMX termination connector is required at the last
luminaire in the link. Refer to
“Connecting Data and Power” on page 17
for more information
regarding the construction of this connector.
Note:
After 10 seconds of inactivity, the menu display will change to the default state showing the
address.
To connect luminaires for simultaneous testing:
Step
1. At last luminaire, install a DMX termination connector into DATA THRU XLR connector.
Step
2. At master luminaire Menu Display, press [Menu].
Figure 4-2: Testing Setup
To run tests:
Step
1. Press [Menu].
Step
2. Press [Up] / [Down] arrows until
Test
appears. Press [Enter].
Step
3. Use [Up] / [Down] arrows to select a parameter to test. Refer to
“VL3015 Spot Menu
System Function Chart” on page 67
or
“VL3515 Menu System Function Chart” on page 71
for a complete list of test parameters which can be chosen.
Step
4. Press [Enter] to run test.
Step
5. Press [Menu] to stop test at any time.
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
DMX Termination Connector
Master Luminaire
Luminaire 1
Luminaire 2
Data Thru
Data Thru
Содержание VL3015 Spot Luminaire
Страница 1: ......
Страница 13: ...FOREWORD 02 9679 0002 A 27 August 2013 xi ...
Страница 14: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL xii 27 August 2013 02 9679 0002 A ...
Страница 18: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL xvi 27 August 2013 02 9679 0002 A ...
Страница 38: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL 20 27 August 2013 02 9679 0002 A Notes ...
Страница 96: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL 78 27 August 2013 02 9679 0002 A Notes ...
Страница 117: ......