I
NSTALLATION
: I
NSTALLATION
P
ROCEDURES
2
0 2 . 9 6 7 9 . 0 0 0 2 A
2 7 A u g u s t 2 0 1 3
17
Floor Mounting the Luminaire
The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided that the
mounting surface is flat and sturdy.
Figure 2-6: Floor Mounting
Connecting Data and Power
A maximum of 32 luminaires may be connected in any one DMX data link.
Note:
This maximum limit applies to the luminaire "daisy chain" only. Your system or console may
require fewer luminaires on a single data link path. Consult your console documentation for more
information.
To connect power and data:
Step
1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step
2. If required, connect additional data cables from DATA THRU connectors to DATA IN
connectors of remaining luminaires in link.
Step
3. At last luminaire in link, install a DMX termination connector at DATA THRU connector.
(Luminaires and other devices on the same DMX chain may not function properly without
termination.)
Step
4. Connect AC input cable connector to power input source.
Step
5. Dress AC input and data cables and secure them so that they will not interfere with
luminaire head and yoke movement.
Figure 2-7: Connecting Power and Data
Luminaire Enclosure
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
DMX Termination Connector
Data Thru
Data Thru
Data In
(from console)
Содержание VL3015 Spot Luminaire
Страница 1: ......
Страница 13: ...FOREWORD 02 9679 0002 A 27 August 2013 xi ...
Страница 14: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL xii 27 August 2013 02 9679 0002 A ...
Страница 18: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL xvi 27 August 2013 02 9679 0002 A ...
Страница 38: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL 20 27 August 2013 02 9679 0002 A Notes ...
Страница 96: ...VARI LITE VL3015 VL3515 SPOT LUMINAIRE USER S MANUAL 78 27 August 2013 02 9679 0002 A Notes ...
Страница 117: ......