VARI
❋
LITE - VLX3 LED W
ASH
L
UMINAIRE
S
ERVICE
M
ANUAL
2 0
0 2 . 9 7 0 3 . 0 0 1 0 0
Main Control Board (MCB) Replacement
Tools:
•
#2 Phillips screwdriver
WARNING:
Ensure that power is completely removed (disconnected) from luminaire before
attempting any work.
To remove MCB assembly:
Step
1. Remove power from luminaire and allow unit to completely cool.
Step
2. As illustrated in
, remove MCB side head cover (side with closest to the two
lenses) by loosening the four quarter-turn Dzus fasteners.
Note:
Each cover is secured by a safety tether. Locate clip attached to cover and unclip tether
Figure 2-3: VLX3 Wash MCB Removal
Main Control Board (MCB)
CAUTION:
Remove power and
allow fixture to cool.
Quart-Turn Dzus
Fasteners (x4)
Head Cover