2
C interfaces
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Exit
5. Load I2DAT with next data byte from Master Transmit buffer.
6. Write 0x04 to I2CONSET to set the AA bit.
7. Write 0x08 to I2CONCLR to clear the SI flag.
8. Increment Master Transmit buffer pointer
9. Exit
11.9.14 State:
0x30
Data has been transmitted, NOT ACK received. A Stop condition will be transmitted.
1. Write 0x14 to I2CONSET to set the STO and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
11.9.15 State:
0x38
Arbitration has been lost during Slave A Write or data. The bus has been
released and not addressed Slave mode is entered. A new Start condition will be
transmitted when the bus is free again.
1. Write 0x24 to I2CONSET to set the STA and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
11.9.16 Master Receive States
11.9.17 State:
0x40
Previous state was State 08 or State 10. Slave A Read has been transmitted,
ACK has been received. Data will be
received and ACK returned.
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
11.9.18 State:
0x48
Slave A Read has been transmitted, NOT ACK has been received. A Stop
condition will be transmitted.
1. Write 0x14 to I2CONSET to set the STO and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit