© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
User manual
Rev. 01 — 15 August 2005
130
Philips Semiconductors
UM10139
Volume 1
Chapter 10: UART1
10.3.17 UART1
Transmit
Enable Register (U1TER - 0xE001 0030)
LPC2141/2/4/6/8’s U1TER enables implementation of software and hardware flow control.
When TXEn=1, UART1 transmitter will keep sending data as long as they are available.
As soon as TXEn becomes 0, UART1 transmission will stop.
describes how to use TXEn bit in order to achieve software flow control.
Fig 22. Autobaud Mode 0 and Mode 1 waveform
a) Mode 0 (Start bit and LSB are used for auto-baud)
b) Mode 1 (only Start bit is used for auto-baud)
UART1 Rx
Start bit
LSB of 'A' or 'a'
U1ACR Start
rate counter
UART1 Rx
Start bit
LSB of 'A' or 'a'
rate counter
start
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
parity stop
'A' (0x41) or 'a' (0x61)
'A' (0x41) or 'a' (0x61)
start
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
parity stop
U1ACR Start
16 cycles
16xbaud_rate
16 cycles
16 cycles
16xbaud_rate