5. SM40 MODULES
5-7
5
5.2.3
Relay Termination Board
LBB 1379/00
Function
This card will be used in an SM40 PA System to route the 100 volt audio output of a call and music
amplifier to a maximum of eight loudspeaker zones (see circuit diagram on opposite page).
The card is therefore equipped with eight relays to be activated by the make contacts of the eight relays of a
Control Relay Card (CRC) in a SM40 system which in turn can be activated by programming the system.
Installation
This card should be installed in place of a normal termination board (replaces it) inside an SM40 system
and should be connected via 2 standard flat cables of 16 wires, to the Control Relay Card. See Termination
Board Connectors.
The power supply voltage for the relays is achieved from the internal SM40 power supply (+15 Volt and
-15 Volt) via a standard 2-wire flat
cable (see attached connecting
diagram).
Remarks
■
The card is protected against
reversed connection of the
power supply voltage.
■
Instead of the internal power
supply unit of the SM40 system
an external power supply unit
of approx. 30 volt can be used
to activate the relays.
■
Depending on the required
audio power in the loudspeaker
zones, 1 up to 4 call and/or
music amplifiers can be
connected to this card creating
8 loudspeaker zones.
NOTE:
Relays are de-activated
during calls via the Relay
Termination Board (RTB).
F ro m :
Ca ll Amp lifier
F ro m:
Music Amplifier
X1 - 1
X1 - 2
X1 - 3
X1 - 4
-
+
-
+
-
+
X3 - 2
X3 - 1
X2 - 1
X2 - 2
X3 - 6
X3 - 5
X2 - 3
X2 - 4
X3 - 1 0
X3 - 9
X2 - 5
X2 - 6
X1 - 5
X1 - 6
X1 - 7
X 1 - 8
-
+
X1 - 9
X1 - 10
X1- 1 6
X1- 1 5
X1- 1 4
X1- 1 3
X1- 1 2
X1- 1 1
X2- 1 6
X2- 1 5
X4 - 13
X4 - 1 4
X2 - 1 4
X2 - 1 3
X4 - 9
X4 - 1 0
X2- 1 2
X2- 1 1
X4 - 5
X4 - 6
X2 - 9
X4 - 1
X4 - 2
X2 - 8
X2 - 7
X3 - 1 3
X3 - 1 4
-
+
-
+
-
+
-
+
-
+
- 1 5 V
+ 1 5 V
F ro m:
Ca ll Amplifier
F ro m:
Music Amplifier
F ro m :
Ca ll Amp lifier
F ro m:
Mu sic Amplifie r
F ro m :
Ca ll Amp lifier
F ro m:
Mu sic Amplifie r
X2 - 1 0
T o L S
zone A
T o L S
z o n e B
T o L S
z o n e C
T o L S
z o n e D
T o L S
zone E
T o L S
zone F
T o L S
z o n e G
T o L S
z o n e H
Rela y Te rmina tion Board
L BB 1 3 79 /0 0
Contro l Re la y Ca rd
L BB 13 5 6 /0 0
Circuit diagram
Содержание LBB 1330
Страница 2: ......
Страница 4: ...SM40 SOUND DISTRIBUTION SYSTEM ii This page has been left blank intentionally ...
Страница 6: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 ...
Страница 8: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 2 1 ...
Страница 10: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 4 1 ...
Страница 12: ...2 UNPACKING AND INSTALLATION 2 ...
Страница 16: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 ...
Страница 18: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 2 3 ...
Страница 20: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 4 3 ...
Страница 21: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 5 3 ...
Страница 22: ...4 OPERATING AND PROGRAMMING THE SM40 SYSTEM 4 ...
Страница 59: ...4 OPERATING AND PROGRAMMING THE SM40 SYSTEM 4 37 4 This page has been left blank intentionally ...
Страница 60: ...5 SM40 MODULES 5 ...
Страница 64: ...5 SM40 MODULES 5 4 5 ...
Страница 66: ...5 SM40 MODULES 5 6 5 ...
Страница 68: ...5 SM40 MODULES 5 8 5 ...
Страница 70: ...5 SM40 MODULES 5 10 5 ...
Страница 77: ...5 SM40 MODULES 5 17 5 This page has been left blank intentionally ...
Страница 78: ...5 SM40 MODULES 5 18 5 b a c ...
Страница 80: ...5 SM40 MODULES 5 20 5 IMPORTANT Ensure the interconnection cable is positioned correctly ...
Страница 81: ...5 SM40 MODULES 5 21 5 ...
Страница 82: ...5 SM40 MODULES 5 22 5 ...
Страница 84: ...5 SM40 MODULES 5 24 5 ...
Страница 85: ...5 SM40 MODULES 5 25 5 ...
Страница 86: ...5 SM40 MODULES 5 26 5 ...
Страница 88: ...5 SM40 MODULES 5 28 5 ...
Страница 90: ...5 SM40 MODULES 5 30 5 ...
Страница 92: ...5 SM40 MODULES 5 32 5 ...
Страница 94: ...5 SM40 MODULES 5 34 5 ...
Страница 96: ...5 SM40 MODULES 5 36 5 ...
Страница 97: ...5 SM40 MODULES 5 37 5 ...
Страница 98: ...5 SM40 MODULES 5 38 5 Surveillance Message Switch Card ...
Страница 100: ...5 SM40 MODULES 5 40 5 ...
Страница 101: ...5 SM40 MODULES 5 41 5 This page has been left blank intentionally ...
Страница 106: ...5 SM40 MODULES 5 46 5 SM40 PHILIPS 6 7 8 9 10 1 2 3 4 5 CALL STATION LBB 9567 ...
Страница 108: ...5 SM40 MODULES 5 48 5 ...
Страница 110: ...5 SM40 MODULES 5 50 5 ...
Страница 112: ...5 SM40 MODULES 5 52 5 ...
Страница 113: ...5 SM40 MODULES 5 53 5 ...
Страница 114: ...5 SM40 MODULES 5 54 5 ...
Страница 115: ...5 SM40 MODULES 5 55 5 ...
Страница 116: ...5 SM40 MODULES 5 56 5 ...
Страница 117: ...5 SM40 MODULES 5 57 5 ...
Страница 118: ...5 SM40 MODULES 5 58 5 ...
Страница 120: ...5 SM40 MODULES 5 60 5 This page has been left blank intentionally ...
Страница 135: ...6 REMOTE PROGRAMMING 1 O PROTOCOL 6 15 6 This page has been left blank intentionally ...
Страница 139: ......