4.4
CALIBRATION OF
THE
INPUT
m
Make
sure
the
analog outputs
are
calibrated
correctly
Locate the trimpotmeters
3247
and
3248
a Select analog input then apply an analog source of the required level
( f o r
0
dBFs
digital) to the
balanced inputs
(always
between
9 and 15
dBu, 1
kHz)
=
Connect a suitable
analog
dB
meter
to
the
analog
balanced
outputs
(L/R)
a Adjust
the
trimpotmeters so
that both outputs give the reading t h a t
corresponds
with the 0 dBFs level as it was
defined during the
calibration of the
outputs.
This
is
always
between
9
and 15 dBu.
Figure
4.2: Location
of trimpots.