Service Modes, Error Codes and Fault Finding
5.
5.5.2
How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
•
By activation of the 'Reset error buffer' command in the
SAM menu.
•
When you transmit the code 062599 with a standard
remote control transmitter.
5.5.3
Error Codes
Table 5-1 Error code overview
Notes:
•
In case of non-intermittent faults, clear the error buffer
before you begin the repair. This to ensure that old error
codes are no longer present.
•
If possible, check the entire contents of the error buffer. In
some situations, an error code is only the result of another
error code and not the actual cause (e.g., a fault in the
protection detection circuitry can also lead to a protection).
•
In case error 70 occurs, the belonging over-voltage line
cause can be located via measuring. (via measuring all 4
voltages simultaneously with an oscilloscope). Chosen
FM242-workshops will be trained how to do so. (special
document will be generated for this).
5.6
The Blinking LED Procedure
Via this procedure, you can make the contents of the error
buffer visible via the front LED (orange colour).This is
especially useful when there is no picture. When no errors are
present, the LED will stay green.
When the SDM is entered, or when code 062500 is entered
with the remote control, the LED will blink the contents of the
error-buffer.
Error-codes
≥
10 are shown as follows:
1.
n long blinks of 750 ms, which is/are an indication of the
decimal digit,
2.
a pause of 1.5 s,
3.
n short blinks (n = 1-9),
4.
when all the error-codes are displayed, the sequence
finishes with a LED blink of 3 s,
5.
the sequence starts again.
Example of error buffer: 12 9 6 0 0
After entering SDM:
1.
1 long blink of 750 ms followed by a pause of 1.5 s,
2.
2 short blinks followed by a pause of 3 s,
3.
9 short blinks followed by a pause of 3 s,
4.
6 short blinks followed by a pause of 3 s,
5.
1 long blink of 3 s to finish the sequence,
6.
the sequence starts again.
5.7
Protections
You can read the error codes of the error buffer via the service
menu (SAM), the blinking LED procedure, or via ComPair. If a
fault situation is detected an error code will be generated and if
necessary, the set will be put in the protection mode. Blinking
of the red LED at a frequency of 5 Hz indicates the protection
mode.
In some error cases, the microprocessor does not put the set
in the protection mode. The error codes are indicated by an
orange front LED.
To get a quick diagnosis the chassis has three service modes
implemented:
•
The Customer Service Mode (CSM): easy way to read out
the status of the set.
•
The Service Default Mode (SDM): start-up of the set in a
predefined way.
•
The Service Alignment Mode (SAM): adjustment of the set
via a menu and with the help of test patterns.
Exceptional ‘protection’ situation
There exists one ‘protection’ (due to too high internal set-
temperature), where the set does not switch to ‘protection’-
mode but to Standby-mode. This protection is not logged into
the error-buffer.
When the set becomes too warm, an ‘On Screen Display’-
message will be showed set is going to switch to Standby. After
some time set can be switched on again. (It is very unlikely this
will happen. For that reason this performance has been
accepted).
Error Device
Description
Item
Diagr.
1
TEA6422D
Audio switch
(only Enhanced)
7798
SC13
2
MSP3451G
Sound proces-
sor
7812
SC14
3
PCF8574-
SCAVIO
I/O expander
SCAVIO
7540
SC8
4
PCF8591
AD-DA expand-
er
7530
SC8
5
FS6377
Clock generator 7570
SC9
6
PCF8574-PSU
I/O expander
PSU
7370
P3
7
24C16 OTC
NVM OTC
7430
SC7
8
24C16 PW
NVM PW
7580
SC9
9
SAA7118
Video decoder
(only Enhanced)
7225
SC5
10
AD9887
ADC/TMDS re-
ceiver
7170
SC4
11
SDA9400
De-interlacer
(only Enhanced)
7280
SC5
12
EP1K30QC
EPLD processor 7656
SC11
13
PDP
I2C error of the
PDP
20
Download comm.
Errors during
downloading
21
CSP comm.
CSP time-out er-
ror
40
Temperature alarm
Detections of
over-tempera-
ture
70
Over voltage
Vs, Va, +5V,
+3V3 overvolt-
age
Black
box
P
71
Vs under voltage
Vs under voltage Black
box
P
72
Va under voltage
Va under voltage Black
box
P
73
+5V under voltage
+5V under volt-
age
Black
box
P
74
+3V3 under v3V3 under volt-
age
Black
box
P
75
DC-PROT
Audio amplifier
protection
Black
box
P
Temperature error
The monitor will switch to standby
automatically.
Please allow cool down.
Содержание FM242
Страница 7: ...Directions for Use EN 7 FM242 AA 3 3 Directions for Use ...
Страница 8: ...Directions for Use EN 8 FM242 AA 3 ...
Страница 9: ...Directions for Use EN 9 FM242 AA 3 ...
Страница 31: ...Electrical Diagrams and PWB Layouts 31 FM242 AA 7 Audio Panel Supply Right High ...
Страница 66: ...66 FM242 AA 7 Electrical Diagrams and PWB Layouts Personal Notes Personal Notes ...
Страница 90: ...Revision List EN 90 FM242 AA 11 11 Revision List First release ...