1-8-6
B4(3D)_AIR
5. Saving The Pre-Operation OPU DATA
OPU DATA before performing the OPU DATA write is saved in a folder automatically.
5-1. When the OPU DATA write operation has been completed successfully, a folder named [FactoryInfo] is
created in the application folder (OpuDataWriter).
5-2. In the [FactoryInfo] folder, a folder is created monthly in which text file data are saved.
This text file is created with a file name of the OPU serial number and contains the pre-operation OPU DATA.
5-3. The text file is necessary for analyzing the defective BD Mechanism. Submit this text file with the defective
BD Mechanism as necessary to the appropriate managing Department.
2042
LdParamClear ERROR0
Cannot initialize LD Parameter.
2043
LdParamClear ERROR1
Cannot initialize LD Parameter.
2044
LdParamClear TIME OUT
Cannot initialize LD Parameter (TimeOut).
2051
IopSet NG
Iop Set Error
2052
IopSet ERROR0
Iop Set Error
2053
IopSet ERROR1
Iop Set Error
2054
IopSet TIME OUT
lop Set Error (TimeOut)
2055
IopSet ERROR0
Iop Set Error
2056
IopSet ERROR1
Iop Set Error
2057
IopSet TIME OUT
lop Set Error (TimeOut)
2058
CD Iop LIMIT NG
CD Iop exceeds limit value.
2059
DVD Iop LIMIT NG
DVD Iop exceeds limit value.
2060
BD Iop LIMIT NG
BD Iop exceeds limit value.
2081
LdParamVerify NG
LD Parameter Verify Error
2091
AtapiComCheck NG
BE start Error.
2101
ID4 OFF NG
Cannot set ID4 OFF.
2111
SET BOR RATE NG
Failed to change Serial Connection Rate.
2200
Genaration NG
Generation detect failure.
6001
Factory Info save Error
Failed to create FactoryInfo file.
6002
Factory Info save Error
Failed to create FactoryInfo file.
6100
Factory Info save Error
Failed to create FactoryInfo file.
Error Code
Error
Description
Year(2010)Month(12)