Battery-Monitor BLS
REV 1A – APR 2019 - Software Version 1A
page 12
- Alarm auto off
0-255 sec (0 = always on)
The buzzer can be configured for individual alarms. Depending on the configuration, the alarm
switches on for the following alarm states and remains switched on until all pending alarms have
been canceled. If an alarm has been acknowledged and a new alarm is added, the buzzer will be
reactivated.
Battery 1
capacity alarm
Adjustable (10 - 80%)
battery empty (20%)
determined by battery management
battery deep discharge (0%)
determined by battery management
overvoltage adjustable
adjustable (14 - 32 V)
(Over) temperature
adjustable (40 - 60 ° C)
Battery 2
undervoltage
adjustable (9-24V)
overvoltage
adjustable (14-32V)
Battery 3
undervoltage
adjustable (9-24V)
overvoltage
adjustable (14-32V)
The voltage alarms must necessarily be adapted for 24V batteries!
By briefly pressing the respective line, the audible alarm can be switched on or off. At long pressure
(> 2s) the respective threshold value can be edited.
5. OPERATION
On the main page you can switch between the 2 main screens via the lower buttons:
battery and charger, provided that a philippi charger ACE with interface ACE-LIN is installed.
Otherwise, only the battery screen is available.
The lower buttons have the following functions:
Batteries: If a shunt SHE 300 is connected, the charge status of the battery system can be read.
Pressing this button switches to the battery screen.
AC mains: If an ACE charger is connected, the current mains voltage is displayed. If no mains voltage
is applied to the charger this will be displayed accordingly.
Pressing this key switches to the loading screen.
SETUP: Here the settings of the battery system can be made. See chapter 4.