2. Keep pressing the button for 3
seconds then green LED will be
off, release the button within 2
seconds.
3. Device has been reset.
Green LED light
flashes once every
one second and
last for 30 sec-
onds.
Adding a node ID allocated by Z-Wave™ Controller means inclusion.
Removing a node ID allocated by Z-Wave™ Controller means exclusion.
The situation of including/excluding of the node ID can be checked
from the Z-Wave™ Controller.
Function Reset: The Reset procedure can only be used when PAD18
cannot be recognized by the Z-Wave™ Primary Controller.
LED Light Indication
The LED light indicates the different modes of the PAR02
State Type
LED Indication
Have not
learned IR
code
When powered for the first time, the device’s red LED light will flash on
and off alternately and repeatedly at 250 microsecond intervals. This
implies device haven't learned the IR code.
Without
Node ID
Under normal operation, when the PAR02 has not been allocated a
node ID, the green LED light will flash on and off alternately at 1-
second intervals. By pressing the On/Off button, green LED light will
stop flashing temporarily.
Learning
Flashes when learning is successful
Operation
Mode
When PAR02 in o
peration
mode. Green LED light will on.
When someone is in the detection range, red LED light will flash twice.
Standby
Mode
When PAR02 in standby mode. Red LED light will on.
Adjustment
Mode
In adjustment Mode, Green LED light will
toggle on and off at 250 mi-
crosecond intervals.
Z-Wave™ Message Report
When PAR02 detected people in the detection range per 30 second, the device
will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Motion Detection, Unknown Location (0x08)
5