background image

Standby mode

If device learning IR completed, device will in standby mode.
In this mode you can clear IR code

reset 

Z-Wave™ Dongle and

change mode to 

Adjustment or operation mode.

Function

Description

Annotation

Change mode

Short press the button on the top of the device.
Change to operation mode.

Long press the button on the top of the device.
Change to adjustment mode.

Z-Wave™

Please refer to Z-Wave™ Network.

Reset IR Code

Please refer to IR Learning.

IR Sending

Press  the  button  on   the  left  back  of  the  device
twice in 2  second.Confirm the function of the IR
code is correct.

Adjustment mode

If device learning IR completed, device will in standby mode. Long
press the button on the top of the device,  then green LED will
flash. This implies device is in adjustment mode. 

When someone is in the detection range 2 second, buzzer will

beep. Number of beep is related to the distance of the someone.

You can adjust device fixed angle to adjust the detection range of

the PAR02.

Long press the button on the top of the device, return to standby 
mode.

Operation mode

If device learning IR completed, device will in standby mode. Short
press the button on the top of the device, then green LED will on.
This means device is in operation mode. 

Every time the device enters the operation mode, the device will
scan the space first. At this time, please keep the front clearance
of the equipment. Wait for the beep to stop , the device will start to
operate.

When someone is in the detection range, the table below provides

an operation of detect time.

Detect time

Operation

 

10 second

Buzzer will beep twice.

30 second

Buzzer will beep five times.

Default send notification time.

60 second

Buzzer will beep twice.

Send the IR code.

Default send notification time.

Can use Z-Wave™ Controller to send command Simple AV Con-

trol, then PAR02 will send IR Code.

Command

class

Key Attributes

Command

Description

 Simple AV

Control Set

1

0027 (HEX)

Device in operation mode, send IR 
code.

Short press the button on the top of the device, return to standby
mode

Adding to Z-Wave

 Network

3

Содержание PAR02

Страница 1: ...e upgrade Only for Z Wave Dongle Specification Power supply DC power 5V USB type C RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 Mhz US Canada 922 927 Mhz JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Transceiver RF Maximum Power Peak 10dBm Peak RF Maximum Power Average 10dBm Average RF Range Minimum 40 met...

Страница 2: ...p 1 Press the button on the left back of the device twice in 2 second Then green LED Light will flash at 1 second intervals and red LED light will off Step 2 Use the remote control to press the power button to learn IR code If IR learning completed the device s green LED light will fast flash twice Notice If IR learning failed the device s will return to previous status Repeat step1 to Learn IR Co...

Страница 3: ...ngle to adjust the detection range of the PAR02 Long press the button on the top of the device return to standby mode Operation mode If device learning IR completed device will in standby mode Short press the button on the top of the device then green LED will on This means device is in operation mode Every time the device enters the operation mode the device will scan the space first At this time...

Страница 4: ...Classic Inclusion 1 Put your Z Wave controller into inclusion mode by following the in structions provided by the controller manufacturer 2 Press the include button three times within 3 seconds to enter inclusion mode SmartStart 1 The product has a DSK string Key in the first five digits to initiate the SmartStart process or scan QR code Ex DSK 13499 30083 53564 10017 46484 46801 61416 39855 2 Sma...

Страница 5: ...rnately and repeatedly at 250 microsecond intervals This implies device haven t learned the IR code Without Node ID Under normal operation when the PAR02 has not been allocated a node ID the green LED light will flash on and off alternately at 1 second intervals By pressing the On Off button green LED light will stop flashing temporarily Learning Flashes when learning is successful Operation Mode ...

Страница 6: ...e will be nonfunctional Only PAR02 Z Wave Dongle has been updated Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None Security 2 1 None Supervision 1 None Transport Service 2 None Version 1 Highest granted Security Class Association 2 Highest granted Security Class Multi Channel Association 2 Highest granted Security Class Associatio...

Страница 7: ...ined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for ...

Отзывы: