Z-Wave
™
Configuration
No.
Name
Size
(Byte)
Default
Value
Description (Info)
1
Report Period
1
3
1 ~ 6
In operation mode, the report time
of a person within the detection
range is 10 seconds per scale and
preset to 3 (30 seconds), which
means that the report time will
only be reported if the person
continues within the detection
range for more than 30 seconds.
Notice 1:
Always Reset a Z-Wave™ device before trying to add it
to a Z-Wave™ network.
Notice 2:
PAR02 can be operated in any Z-Wave™ network
which provided by other certified Z-Wave™ Controllers. All non-
battery operating devices act as repeaters to increase the stability
and reliability of the Z-Wave™ network.
Over-the-Air (OTA) Firmware Update
The device is supported with Z-Wave™ firmware update via OTA.
1.
Set the Z-Wave™ Controller into the firmware update mode.
2.
Choose the hex file to update the firmware.
3.
Wait 10~15 minutes for completing the OTA process.
4.
Result of OTA will show in Z-Wave™ Controller log.
During the OTA process, please DO NOT remove the power,
otherwise, the firmware will be broken, and the device will be
nonfunctional. Only PAR02 Z-Wave™ Dongle has been updated.
Z-Wave™ Supported Command Class
Command Class
Version
Required Security Class
Z-Wave Plus™ Info
2
None
Security
1
None
Security 2
1
None
Supervision
1
None
Transport Service
2
None
Version
1
Highest granted Security Class
Association
2
Highest granted Security Class
Multi-Channel Association
2
Highest granted Security Class
Association Group Information
3
Highest granted Security Class
Manufacturer Specific
1
Highest granted Security Class
Device Reset Locally
1
Highest granted Security Class
Power level
1
Highest granted Security Class
Simple AV Control
1
Highest granted Security Class
Firmware Update Meta Data
5
Highest granted Security Class
Configuration
4
Highest granted Security Class
Notification
8
Highest granted Security Class
Indicator
3
Highest granted Security Class
Central Scene
3
Highest granted Security Class
CAUTION
Choosing a Suitable Location
1.
The suitable ambient temperature for the module/device is
0°C~40°C.
2.
Do NOT place the module/device direct under sunlight, in a
humid place or in any location where they may contact
moisture, dirt, dust.
3.
Do NOT place the module/device where exists combustible
substances or any source of heat, fires, radiators, boiler etc.
6