Philio Technology Corporation PAN03 Скачать руководство пользователя страница 9

 

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

 

 

Company of License Holder

Philio Technology Corporation

 

Address of License Holder

8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New 

Taipei City 24257,Taiwan(R.O.C)

 

www.philio-tech.com 

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. 

 

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. 

 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to

 

radio communications. 

 

However, there is no guarantee that interference will not occur in a particular installation. 

 

If this equipment does cause harmful interference to radio or television reception, which

 

can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one of the following measures:

 

• 

Reorient or relocate the receiving antenna.

 

• 

Increase the separation between the equipment and receiver.

 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

 

• 

Consult the dealer or an experienced radio/TV technician for help.

 

This device complies with Part 15 of the FCC Rules. Operation is subject

 

to the following two conditions:

 

(1) This device may not cause harmful interference, and

 

(2) This device must accept any interference received, including interference that may cause 

undesired operation.

 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment.

 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter.

 

 

警語

警語

警語

警語: 

: : 

 

「取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材,

,非經核准

非經核准

非經核准

非經核准,

,公司

公司

公司

公司、

、商號或使用者均不得擅自變更頻

商號或使用者均不得擅自變更頻

商號或使用者均不得擅自變更頻

商號或使用者均不得擅自變更頻

率、

、加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能。

 

低功率射頻器材之使用不得影響飛航安全及干擾合法通信

低功率射頻器材之使用不得影響飛航安全及干擾合法通信

低功率射頻器材之使用不得影響飛航安全及干擾合法通信

低功率射頻器材之使用不得影響飛航安全及干擾合法通信;

;經發現有干擾現象時

經發現有干擾現象時

經發現有干擾現象時

經發現有干擾現象時,

,應立

應立

應立

應立

即停用

即停用

即停用

即停用,

,並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用。

 

前述合法通信

前述合法通信

前述合法通信

前述合法通信,

,指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信。

。低功率射頻器材須忍受合法通

低功率射頻器材須忍受合法通

低功率射頻器材須忍受合法通

低功率射頻器材須忍受合法通

信或工業

信或工業

信或工業

信或工業、

、科學及醫療用電波輻射性

科學及醫療用電波輻射性

科學及醫療用電波輻射性

科學及醫療用電波輻射性電機設備之干擾

電機設備之干擾

電機設備之干擾

電機設備之干擾。」

。」

。」

。」

 

 

 

Содержание PAN03

Страница 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Страница 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Страница 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Страница 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Страница 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Страница 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Страница 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Страница 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Страница 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Отзывы: