![Philio Technology Corporation PAN03 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/philio-technology-corporation/pan03/pan03_manual_1538000007.webp)
7
32767s
9
RF off
command mode
1
0-3
0
0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on
10
Edge or Pulse
mode or
Edge-Toggle
mode
1
1-3
1
1
:
Edge mode
2
:
Pulse mode
3
:
Edge-Toggle mode
11
Manual Switch
Report mode
1
0-1
1
0 : Disable
1 : Enable
14
Watt differential
report mode
1
0-4
1
0 : Disable
1 : 5%
2 : 10%
3 : 15%
4 : 20%
3-1
Watt
Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN03 will report its
instant power consumption every 1 hour to Group1 node. The maximum interval
to report its instant power consumption is 45 hours (5s*32767/3600=45hr). If the
setting value is 0, the auto report function of meter Watt will be disabled.
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN03 will report its
Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report
function of meter KW/h will be disabled.
3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 1100, when the load current of Relay1 over this value, PAN03 will
send current meter report to warn the Group1 node, the Range of the setting value
is from 10 to 1100, and the default value is 1100.
3-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, if the
setting value is 10000, when the Accumulated Power Consumption of Relay1 over
this value, PAN03 will send KWH meter report to warn the Group1 node, minimum
value is 1KWh and default value is 10000 kWh.
3-5 Restore switch state mode:
Whenever the AC power return from lost, PAN03 will restore the switch state which
could be SWITCH OFF
、
LAST SWITCH STATE
、
SWITCH ON. The default setting
is LAST SWITCH STATE.
3-6 Manual On/Off Mode:
The On/Off function of S1
、
S2 and learn switch can be disabled or enabled by this
parameter, default value is Enable. But the learning operation won’t be affected.
When manual On/Off function is disabled, the RF command can only switch On
but not Off. This is useful function for keeping the device in switch on state.
3-7 LED indication mode:
3-7-1 Show Switch State
:
When switch is on, LED is on. When switch is off, LED is
off. The default setting is Show Switch State.
3-7-2 Show Night mode
:
When switch is on, LED is off. When switch is off, LED is
on.
3-7-3 One Flash mode
:
When the state of switch changes, LED will be on only one
second, then LED keeps off.
3-8 Auto off timer
:
Whenever PAN03 switches to on, the auto off timer begin to count down. After the
timer decrease to zero, it will switch to off automatically. However if Auto off timer
is set as 0, the auto off function will be disabled. The default setting is 0.
3-9 RF off command mode
Whenever a switch off command, BASIC_SET
、
BINARY_SWITCH_SET
、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
3-9-1 Switch Off
:
It switches to OFF state. The default setting is Switch Off.
3-9-2 Ignore
:
The switch off command will be ignored.
3-9-3 Switch Toggle
:
It switches to the inverse of current state.
3-9-4 Switch On
:
It switches to ON state.
3-10 Edge mode
、
、
、
、
Pulse mode and Edge-Toggle mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle
mode, default value is Edge mode.
3-10-1 Edge mode: this mode is suitable for the bi-stable wall switch that has indicator
point on the switch, and the same position correspond to same state of relay1.
If the PAN03 relay change the state because of receiving Z-Wave RF
command, it may need two times of change (switch on to off or switch off to on)